Schneider C11E6TM025B | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 3d, 25A rating TMD trip unit,connectors
Schneider C11E6TM025B Description
It is a ComPacT NSXm molded case circuit breaker, 25A, 16kA at 415VAC, for all LV standard applications.
It offers new features like Everlink technology, DIN rail and plate mounting capability.
It embeds new spring type auxiliaries externally visible.
ComPacT NSXm is one of the smallest MCCB on the market, 108mm (W) x 137mm (H) x 80mm (D).
This is a 4 poles version with an embedded thermal-magnetic trip unit.
It ensures compliance with international standards (IEC 60947/CCC/EAC) and marine specifications.
The Schneider C11E6TM025B surge protector is part of Schneider Electric’s SurgeArrest Performance series. It is designed to protect electronic devices and appliances from power surges, spikes, and lightning strikes. Here are some key features and specifications:
- Voltage Protection: Offers protection against transient voltage surges and spikes.
- Response Time: Provides a quick response time to divert excess voltage away from connected equipment.
- EMI/RFI Noise Filtering: Helps to reduce electromagnetic interference (EMI) and radio frequency interference (RFI) that can affect equipment performance.
- Indicator Lights: Typically includes LED indicator lights to show operational status and protection mode.
- Circuit Breaker: Integrated circuit breaker for overload protection.
- Joule Rating: Indicates the amount of energy the surge protector can absorb before it needs to be replaced.
- Plug Type: Usually features a standard plug for easy connection to wall outlets.
- Compatibility: Suitable for various electronic devices and appliances, including computers, TVs, home entertainment systems, and more.
- Design: Compact and often designed to be wall-mountable for convenience.
- Warranty: Typically comes with a warranty to cover connected equipment if damaged while properly connected to the surge protector.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63E |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 25 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | E 16 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 2.83 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 25 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12 cm |
| Package 1 Width | 13 cm |
| Package 1 Length | 22 cm |
| Package 1 Weight | 1.6 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 254.49 kg |
Main Document
Main Document
Data Sheet : C11E6TM025B
Main Document
Data Sheet : C11E6TM025B
Reviews (0)
Be the first to review “Schneider C11E6TM025B | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 3d, 25A rating TMD trip unit,connectors” Cancel reply
Reviews
There are no reviews yet.