schneider A9F87325 | Miniature circuit-breaker, Acti9 iC60H, 3P, 25 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
schneider A9F87325 | Miniature circuit-breaker, Acti9 iC60H, 3P, 25 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
schneider A9F87325 description
Introduction
Circuit breakers are essential in protecting electrical systems from overcurrents and short circuits. This article will explore the Schneider A9F87325, a miniature circuit breaker (MCB) known for its robust performance and safety features.
Schneider A9F87325
The Schneider A9F87325 is a 1-pole, 25A MCB from the Acti9 series. It features a C curve, which is ideal for protecting circuits with moderate inrush currents, such as lighting and distribution circuits. This MCB is designed for both residential and commercial applications, offering reliable protection and operational efficiency.
How Circuit Breakers Work
Circuit breakers protect electrical systems by automatically cutting off the power supply when an overcurrent or short circuit is detected. They monitor the current flow and trip to stop the flow of electricity when anomalies are found, thus preventing damage to the electrical circuit.
Types of Circuit Breakers
There are various types of circuit breakers, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), and more. Each type has its specific function, ranging from protecting against overloads and short circuits to detecting residual currents.
Importance in Safety
Circuit breakers are crucial for electrical safety. They help prevent potential hazards like fires, equipment damage, and electric shocks by interrupting overcurrents and short circuits. Their role in safeguarding electrical systems is indispensable.
Installation Process
Installing a circuit breaker such as the Schneider A9F87325 involves several steps:
- Turn off the main power: Ensure the main power supply is off to avoid any accidents.
- Identify the circuit: Determine where the MCB will be installed.
- Connect the MCB: Securely connect the MCB to the circuit, making sure all connections are tight and correct.
- Test the installation: After installation, test the MCB to ensure it trips and resets correctly.
Maintenance Tips
Regular maintenance of circuit breakers is essential to ensure their proper functioning:
- Periodic testing: Regularly test the MCB to ensure it operates correctly.
- Check for damage: Inspect the MCB for any physical damage or signs of wear.
- Replace faulty units: Replace any malfunctioning MCBs promptly to maintain safety.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 25 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60947-2 EN 60898-1 IEC 60898-1 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 15 kA 100 % conforming to EN 60947-2 - 125...180 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| Net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.400 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 347.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.200 cm |
| Package 2 Width | 9.800 cm |
| Package 2 Length | 22.200 cm |
| Package 2 Weight | 1.458 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 16.525 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18470 | Miniature circuit-breaker, Acti9 C120H, 3P, 125 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews