schneider A9F94116 | Miniature circuit-breaker, Acti9 iC60L, 1P, 16 A, C curve, 6000 A (IEC 60898-1), 25 kA (IEC 60947-2)
Description
schneider A9F94116 | Miniature circuit-breaker, Acti9 iC60L, 1P, 16 A, C curve, 6000 A (IEC 60898-1), 25 kA (IEC 60947-2)
schneider A9F94116 description
Introduction
Circuit breakers are vital components in any electrical system, providing essential protection against overcurrents and short circuits. This article will focus on the Schneider A9F94116, a miniature circuit breaker (MCB) that combines reliability with advanced features for effective circuit protection.
Schneider A9F94116
The Schneider A9F94116 is a 2-pole, 16A MCB from the Acti9 series, featuring a C curve. This MCB is designed to handle moderate inrush currents, making it suitable for a variety of applications in residential and commercial settings. The 2-pole design allows for protection of both live and neutral wires, enhancing its versatility.
How Circuit Breakers Work
Circuit breakers are safety devices that protect electrical systems by interrupting the power supply when they detect an overcurrent or short circuit. They continuously monitor the current flow and trip to stop electricity when irregularities are detected, thus preventing potential damage and ensuring system safety.
Types of Circuit Breakers
Circuit breakers come in various types, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), and others. Each type serves a specific purpose, from protecting against overloads and short circuits to detecting residual currents that could indicate a fault.
Importance in Safety
The importance of circuit breakers in maintaining electrical safety cannot be overstated. They help prevent fires, damage to equipment, and electric shocks by interrupting circuits during overloads and short circuits. Properly functioning circuit breakers are crucial for ensuring the safety and longevity of electrical systems.
Installation Process
To install the Schneider A9F94116 circuit breaker, follow these steps:
- Turn off the main power: Ensure the main power supply is turned off to prevent any accidents.
- Identify the circuit: Determine the circuit where the MCB will be installed.
- Connect the MCB: Attach the MCB to the circuit, ensuring all connections are secure and correctly configured.
- Test the installation: After installation, test the MCB to ensure it trips and resets correctly.
Maintenance Tips
Regular maintenance is key to ensuring the continued effectiveness of your circuit breaker:
- Periodic testing: Regularly test the MCB to verify that it operates correctly.
- Inspect for damage: Check for any physical damage or signs of wear.
- Replace faulty units: If the MCB shows signs of malfunction, replace it promptly to maintain safety.
Common FAQs
- What is the difference between an MCB and an RCCB?
- An MCB protects against overloads and short circuits, while an RCCB detects residual currents to prevent electric shocks.
- Can MCBs be used in residential applications?
- Yes, MCBs like the Schneider A9F94116 are suitable for both residential and commercial applications.
- What does the ‘C curve’ mean in an MCB?
- The ‘C curve’ refers to the MCB’s tripping characteristics, suitable for circuits with moderate inrush currents.
- How often should an MCB be tested?
- It is recommended to test MCBs at least once a year to ensure they are functioning properly.
- Are MCBs affected by environmental factors?
- Yes, environmental factors such as temperature and humidity can impact MCB performance, so it is important to consider the installation environment.
Conclusion
The Schneider A9F94116 MCB offers reliable protection for electrical circuits, especially those with moderate inrush currents. Proper installation and regular maintenance ensure its effectiveness in safeguarding your electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iC60L |
| poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 16 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 25 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 IEC 60947-2 EN 60947-2 IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 12.5 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 12.5 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 35 kA 50 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 35 kA 50 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 25 kA 50 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 25 kA 50 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 7500 A 50 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 7500 A 50 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 20 kA 100 % conforming to EN 60947-2 - 72 V DC 20 kA 100 % conforming to IEC 60947-2 - 72 V DC 25 kA 100 % conforming to EN 60947-2 - 12...60 V DC 25 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| Height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.3 cm |
| Package 1 Width | 1.8 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 113.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.1 cm |
| Package 2 Width | 9.8 cm |
| Package 2 Length | 22.4 cm |
| Package 2 Weight | 1.422 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 16.13 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F94116
Main Document
Data Sheet : A9F94116
Reviews (0)
Recommended for you
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18469 | Miniature circuit-breaker, Acti9 C120H, 3P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0