Schneider LV431111 | circuit breaker ComPact NSX250B, 25 kA at 415 VAC, TMD trip unit 200 A, 3 poles 3d
Schneider LV431111 | circuit breaker ComPact NSX250B, 25 kA at 415 VAC, TMD trip unit 200 A, 3 poles 3d
Description
Schneider LV431111 | circuit breaker ComPact NSX250B, 25 kA at 415 VAC, TMD trip unit 200 A, 3 poles 3d
Technical Specifications:
-
Type: Circuit Breaker
-
Model: Schneider LV431111 | ComPact NSX250B
-
Nominal Current: 200 Amps
-
Maximum Breaking Capacity: 25 kA at 415 VAC
-
Number of Poles: 3 Poles
-
Trip Unit: TMD (Thermal Magnetic Release)
-
Short-Circuit Protection: The breaker is designed to handle short-circuit currents up to 25 kA at 415 VAC, providing effective protection against electrical faults.
Features:
-
Comprehensive Protection:
The ComPact NSX250B circuit breaker provides reliable protection against overloads, short circuits, and earth leakage, making it ideal for applications where high reliability is required. -
Adjustable Trip Unit (TMD):
The TMD trip unit allows the breaker to be customized according to the specific operational requirements of the system. This flexibility ensures that the breaker provides the optimal protection based on current conditions and load profiles. -
High Short-Circuit Withstand Capacity:
With a breaking capacity of up to 25 kA at 415 VAC, the circuit breaker is capable of withstanding large fault currents, which is particularly important in industrial and commercial environments where high fault currents may occur. -
3-Pole Configuration:
The 3-pole configuration is ideal for three-phase electrical systems, offering efficient protection for all phases of the circuit, ensuring the safety of the electrical network. -
Durability and Long Life:
Built with high-quality materials and advanced technology, this circuit breaker offers exceptional durability and a long service life, even in harsh and demanding environments.
Applications:
-
Industrial and Manufacturing Plants:
The Schneider LV431111 circuit breaker is well-suited for protecting electrical systems in large industrial and manufacturing facilities where high power loads and reliable protection are essential. -
Commercial Buildings:
It can be used in distribution boards of commercial buildings, ensuring the safe and efficient operation of systems such as HVAC, lighting, and power distribution networks. -
Motor Control Systems:
This breaker is ideal for providing protection in motor control centers (MCCs), ensuring the safety of motor-driven equipment such as pumps, fans, and compressors. -
Power Distribution Networks:
Used in electrical distribution systems, this circuit breaker protects circuits and equipment, ensuring the integrity of the entire electrical infrastructure and preventing faults from spreading. -
Data Centers and Critical Infrastructure:
In environments such as data centers, where power reliability is crucial, the Schneider LV431111 breaker ensures continuous and stable power supply to sensitive equipment.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPact |
|---|---|
| Product name | ComPact NSX |
| Range of product | ComPact NSX100...250 |
| Device short name | NSX250B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| [In] rated current | 200 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 5000 cycles at 690 V In 10000 cycles at 690 V In/2 10000 cycles at 440 V In 20000 cycles at 440 V In/2 |
| Mounting support | Backplate |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 200 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Short-time protection pick-up adjustment type Isd | Adjustable |
| [Isd] Short-time protection pick-up adjustment range | 5...10 x In |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 18.5 cm |
| Package 1 Weight | 1.998 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 40.0 cm |
| Package 2 Length | 60.0 cm |
| Package 2 Weight | 24.742 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N18469 | Miniature circuit-breaker, Acti9 C120H, 3P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9N18357 | Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.