No products in the cart.
EasyPact circuit breakers and switches, EasyPact MVS, Low Voltage Products and Systems, Power Circuit breakers & Switches
Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker
Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker
MVS16H3MF2L
Description
Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker
Technical Specifications
- Model: MVS16H3MF2L
- Brand: Schneider Electric
- Series: EP MVS
- Type: Manual Circuit Breaker
- Rated Current: 1600A
- Short-Circuit Withstand Rating: 65kA
- Poles: 3 Poles (3P)
- Type of Operation: Manual (MF)
- Frame Type: Fixed
- Interrupting Capacity: 65kA at 415V
- Protection Function: Overload, Short-circuit, and Earth Fault protection
Key Features
- High Current Rating – With a current rating of 1600A, the MVS16H3MF2L circuit breaker is ideal for large industrial and commercial installations where high power is required.
- High Short-Circuit Withstand Capacity – The breaker offers an impressive 65kA short-circuit withstand rating, ensuring that it can safely handle high fault currents without damaging the electrical system.
- 3-Pole Configuration – The 3-pole design is perfect for three-phase systems, providing balanced protection across all three phases.
- Manual Operation – The manual operation (MF) feature allows operators to manually switch the circuit breaker on and off, making it suitable for applications requiring human intervention and control.
- Fixed Mounting – Designed for fixed installation, this circuit breaker is a reliable and stable option for permanent setups in power distribution panels and control panels.
- Reliable Protection – Protects against overload, short-circuit, and earth fault conditions, enhancing the safety and longevity of the electrical installation.
Applications
The Schneider MVS16H3MF2L circuit breaker is commonly used in various industrial, commercial, and utility applications that require reliable protection for high-power electrical circuits:
- Industrial Power Distribution – Suitable for use in industrial plants, factories, and manufacturing units where large electrical systems need protection.
- Commercial Buildings – Used in high-rise buildings, shopping malls, and office complexes to protect the electrical distribution systems.
- Energy Distribution Systems – Essential for transformer substations and power plants where high current protection is required.
- Critical Infrastructure – Applied in hospitals, data centers, and telecommunication facilities where reliable protection is critical to avoid system failure.
- Renewable Energy Systems – Used in solar and wind energy plants for protecting the electrical circuits against faults and overloads.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| product name | MVS16H |
| Device short name | MVS16H |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3P 3d |
| [In] rated current | 1600 A at 40 °C |
| network type | AC |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category B |
| Trip unit name | ET2I |
| Trip unit technology | Electronic |
| Trip unit rating | 1600 A |
| Network frequency | 50/60 Hz |
|---|---|
| control type | Manually operated |
| Mounting mode | Fixed |
| Mounting support | Base plate Rail |
| Connection position | Vertical Horizontal |
| Location of connection | Rear |
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 12 kV conforming to IEC 60947-2 |
| Circuit breaker CT rating | 1600 A |
| Breaking capacity | 65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2 |
| Electrical durability | Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 |
| Connection pitch | 115 mm without spreader |
| Contact position indicator | Yes |
| [Icm] rated short-circuit making capacity | 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Icw] rated short-time withstand current | 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit protection functions | LI |
| Protection type | Overload protection (long time) Instantaneous short-circuit protection |
| Fault indication | Internal fault Short-circuit Overload |
| Long time pick-up adjustment type Ir | Adjustable 9 settings |
| Long time pick-up adjustment range | 0.4...1 x In |
| Long time delay adjustment type | Adjustable 9 settings |
| [tr] long-time delay adjustment range | 0.5…24 s at 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Instantaneous pick-up adjustment type Ii | Adjustable 9 settings |
| Instantaneous pick-up adjustment range | 1.5...10 x Ir |
| Zone selective interlocking ZSI | With |
| Current sensor rating range | 400/2000 A |
| Maximum breaking time | 25 ms |
| Maximum closing response time | 70 ms |
| Height | 352 mm |
| Width | 422 mm |
| Depth | 297 mm |
| Product weight | 40 kg |
| Standards | IEC 60947-2 |
|---|---|
| Product certifications | GOST IEC CCS CCC |
| Pollution degree | 4 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -5…70 °C |
| Ambient air temperature for storage | -40…85 °C without control unit -25…85 °C with control unit |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 42.0 cm |
| Package 1 Width | 35.0 cm |
| Package 1 Length | 50.0 cm |
| Package 1 Weight | 46.133 kg |
| Warranty | 18 months |
|---|
Reviews (0)
Be the first to review “Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker” Cancel reply
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
Acti 9 Miniature Circuit Breakers - MCBs, C120, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18569 | Vigi C120 – earth leakage add-on block – 4P – 30 mA – class AC
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18470 | Miniature circuit-breaker, Acti9 C120H, 3P, 125 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Acti 9 iK60, Acti 9 iK60, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9K24316 | Miniature circuit-breaker, Acti9 iK60N, 3P, 16 A, C curve, 6000 A (IEC 60898-1)
Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, iC60, Low Voltage Products and Systems
-
0
Reviews