Schneider 50439 | Closed toroid for residual current protection IA – Ø 80 mm
Schneider 50439
Description
Schneider 50439
Schneider 50439: Comprehensive Guide
The Schneider 50439 is an advanced electrical component designed to meet the demanding requirements of modern electrical systems. This comprehensive guide aims to provide a detailed understanding of it, including its features, applications, installation process, benefits, and more.
About Schneider Electric
With a rich history dating back to it, Schneider Electric has emerged as a global leader in energy management and automation solutions. The company’s commitment to innovation, sustainability, and customer satisfaction has cemented its position as a trusted name in the electrical industry.
Detailed Overview of Schneider 50439
it is a versatile and reliable electrical component with the following key features and specifications:
- Robust construction: Built to withstand harsh environmental conditions and ensure long-term durability.
- Advanced functionality: Equipped with innovative features for efficient energy management, enhanced performance, and superior reliability.
- User-friendly design: Easy to install, operate, and maintain, catering to the needs of both professionals and DIY enthusiasts.
Applications of Schneider 50439
Industrial Uses: it finds widespread use in industrial settings for power distribution, motor control, and automation applications, ensuring reliable operation and optimizing energy usage.
Commercial Applications: In commercial buildings, it helps improve energy efficiency, reduce operational costs, and enhance overall performance, contributing to a sustainable environment and cost-effective operations.
Residential Settings: Homeowners benefit from it’s reliable performance, ensuring a stable electrical supply for household needs while promoting energy savings, safety, and convenience.
Installation Process
Installing it is straightforward and can be done following these steps:
- Preparation: Gather all necessary tools, equipment, and materials required for installation.
- Safety First: Adhere to safety guidelines and precautions to prevent accidents and ensure personal safety.
- Mounting: Securely mount it in the designated location using appropriate mounting hardware and techniques.
- Wiring: Connect the electrical wires and cables to it according to the provided instructions, ensuring proper insulation and tight connections.
- Testing: Conduct comprehensive tests and checks to verify proper functionality, performance, and safety of it before putting it into operation.
Advantages of Using Schneider 50439
Schneider 50439 offers several advantages, including:
- Enhanced Efficiency: it optimizes energy usage, leading to cost savings, reduced environmental impact, and improved operational efficiency.
- Reliability: Built to the highest quality standards, it ensures reliable and uninterrupted operation, minimizing downtime and maximizing productivity.
- Flexibility: With its versatile design and advanced features, it can be adapted to a wide range of applications and configurations, providing maximum flexibility, scalability, and customization options.
Comparing Schneider 50439 with Other Products
Compared to similar products, it offers:
- Superior Performance: With its advanced functionality, innovative features, and superior build quality, it outperforms competitors in terms of efficiency, reliability, and overall performance.
- Ease of Use: it’s user-friendly design, intuitive interface, and straightforward installation process make it the preferred choice for professionals and DIY enthusiasts alike.
- Trusted Brand: As a product of Schneider Electric, it benefits from the company’s decades of experience, expertise, and reputation for quality, reliability, and innovation, providing peace of mind and confidence to users.
Troubleshooting and Maintenance
To ensure optimal performance, longevity, and reliability, follow these troubleshooting and maintenance tips:
- Regular Inspections: Periodically inspect it for signs of wear, damage, or deterioration, and address any issues promptly to prevent further damage or malfunction.
- Cleaning: Keep Schneider 50439 clean and free of dust, debris, and contaminants to ensure proper airflow, cooling, and electrical insulation, preventing overheating, electrical issues, and component failure.
- Scheduled Maintenance: Follow the manufacturer’s recommended maintenance schedule and procedures, including lubrication, filter replacement, and component inspection, to ensure peak performance, reliability, and safety of Schneider 50439 throughout its service life.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | VigiPacT |
|---|---|
| Device short name | IA80 |
| Product or component type | Earth leakage current sensor |
| Device application | Equipment monitoring and control |
| Range compatibility | VigiPacT RH10M residual current protection relay VigiPacT RH10P residual current protection relay VigiPacT RH21M residual current protection relay VigiPacT RH21P residual current protection relay VigiPacT RH68M residual current protection relay VigiPacT RH86M residual current protection relay VigiPacT RH86P residual current protection relay VigiPacT RH99M residual current protection relay VigiPacT RH99P residual current protection relay VigiPacT RH197M residual current protection relay VigiPacT RH197P residual current protection relay VigiPacT RHU residual current protection relay VigiPacT RHUs residual current protection relay VigiPacT RMH residual current protection relay |
| current sensor type | A type closed toroid |
| [Ie] rated operational current | 160 A |
| Transformer ratio | 1/1000 |
|---|---|
| Network type | AC/DC |
| Network frequency | 45...440 Hz |
| [Icw] rated short-time withstand current | 85 kA for 0.5 s |
| Residual short-circuit withstand current | 85 kA / 0.5 s conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 1000 V |
| Overvoltage category | IV |
| [Uimp] rated impulse withstand voltage | 12 kV |
| Mounting mode | Fixed (cables) Fixed (plain backplate) Fixed (profiled sheet metal) Fixed (slotted backplate) Clip-on (DIN rail) |
| Calorific value | 3.19 MJ |
| Connections - terminals | Screw connection 0.22 mm² |
| Diameter | 80 mm inner: |
| Cable outer diameter | 40 mm: 95 mm² (maximum) |
| Net weight | 0.42 kg |
| height | 122 mm |
| Width | 150 mm |
| Depth | 44 mm |
| IP degree of protection | Connectors: IP20 IP30 |
|---|---|
| Environmental characteristic | Exposure to damp heat not in service (25...55 °C, RH 95 %) : 28 cycles conforming to IEC 60068-2-30 Salt mist: Kb/2 conforming to IEC 60068-2-52 Exposure to damp heat in service: category C2: 48 hours conforming to IEC 60068-2-56 |
| Pollution degree | Level 3 conforming to IEC 60664-1 |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -55…85 °C |
| Standards | IEC 60947-2 |
| product certifications | CE |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.4 cm |
| Package 1 Width | 13.2 cm |
| Package 1 Length | 16.4 cm |
| Package 1 Weight | 332.0 g |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 40.0 cm |
| Package 2 Length | 60.0 cm |
| Package 2 Weight | 14.046 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download50439
Main Document
Data Sheet : Download50439
Reviews (0)
Recommended for you
-
0
Schneider 56163 | Earth-leakage relay RH21M – 300 mA – 0.06 s – 240 V
-
0
Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V
-
0
Schneider 50441 | closed toroid A type, for Vigirex and Vigilhom, SA200, inner diameter 200 mm, rated current 400 A
-
0
Schneider 50438 | closed toroid A type, for Vigirex and Vigilhom, PA50, inner diameter 50 mm, rated current 85 A
-
0
Reviews
There are no reviews yet.