Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V
Schneider 56130
Description
Schneider 56130
Schneider 56130: Comprehensive Guide
The Schneider 56130 stands as an essential component in contemporary electrical systems, renowned for its reliability and efficiency. This guide aims to delve into it, elucidating its features, applications, installation process, benefits, and more.
About Schneider Electric
With a rich history tracing back to it, Schneider Electric has solidified its position as a global leader in energy management and automation solutions. Renowned for innovation and sustainability, Schneider Electric continues to shape the landscape of the electrical industry.
Detailed Overview of Schneider 56130
it epitomizes versatility and reliability, boasting the following key features and specifications:
- Robust Construction: Engineered to withstand demanding conditions, ensuring longevity and durability.
- Advanced Functionality: Equipped with innovative features for efficient energy management and enhanced performance.
- User-friendly Design: Simple installation, operation, and maintenance cater to professionals and enthusiasts alike.
Applications of Schneider 56130
Industrial Utilization: it finds widespread application in industrial settings, facilitating power distribution, motor control, and automation, thereby enhancing operational efficiency and productivity.
Commercial Applications: In commercial establishments, it optimizes energy consumption, reduces operational costs, and ensures uninterrupted power supply, contributing to sustainability and cost-effectiveness.
Residential Implementations: Homeowners benefit from it’s reliability, ensuring a stable electrical supply for household needs while promoting energy savings and safety.
Installation Process
Installing it follows these steps:
- Preparation: Gather necessary tools and equipment.
- Safety First: Adhere to safety guidelines for accident prevention.
- Mounting: Secure the unit in the designated location.
- Wiring: Connect wires according to provided instructions.
- Testing: Conduct comprehensive tests to ensure functionality.
Advantages of Using Schneider 56130
- Enhanced Efficiency: Optimizes energy usage, leading to cost savings and reduced environmental impact.
- Cost-effectiveness: Offers superior performance at competitive prices.
- User-friendly Design: Simplifies installation, operation, and maintenance, saving time and effort.
Comparative Analysis of Schneider 56130 with Other Products
Schneider 56130 excels due to:
- Distinct Features: Innovative functionalities set it apart from competitors.
- Advantages: Offers superior performance, reliability, and ease of use compared to similar products.
Troubleshooting and Maintenance
Regular inspections and timely maintenance ensure optimal performance and longevity. Identifying common issues and adhering to maintenance protocols are essential for prolonged lifespan.
Customer Feedback and Testimonials
Users praise it for its reliability, efficiency, and user-friendly design. Real-world experiences underscore its efficacy in diverse applications.
Procurement of Schneider 56130
it is available through authorized distributors, retailers, and online platforms, ensuring accessibility and authenticity.
Pricing and Warranty Details
Pricing varies based on factors such as configuration and quantity. Warranty coverage provides peace of mind to customers, ensuring support and assistance in case of issues.
Future Prospects of Schneider 56130
Continuous innovation and development signify promising prospects for it. Schneider Electric’s commitment to advancement ensures its relevance in evolving electrical systems.
Expert Opinions on Schneider 56130
Industry experts recognize it’s efficacy and anticipate its continued prominence in energy management and automation solutions.
Environmental Impact
it incorporates sustainability features, aligning with Schneider Electric’s environmental initiatives, and reducing carbon footprints.
Conclusion
In summary, it emerges as a pivotal component in electrical systems, offering reliability, efficiency, and user-friendliness across industrial, commercial, and residential domains.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | VigiPacT |
|---|---|
| Device short name | RH10M |
| Product or component type | Residual current protection relay |
| Relay application | Protection relay |
| mounting support | DIN rail |
| Earth-leakage protection class | Type A |
| Type of setting | None |
| Residual earth-leakage sensitity adjustment type | Fixed |
| Earth-leakage sensitivity | 0.03 A |
| Earth-leakage time delay | Instantaneous |
| Current sensors compatibility | VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor |
| [Ithe] conventional enclosed thermal current | 8 A |
| Minimum load | 10 mA at 12 V |
| [Us] rated supply voltage | 220...240 V AC 50/60 Hz 55...110 % |
| Power consumption in VA | 4 VA |
| Monitored distribution system | 1000 V - AC at 50/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum) |
| Earthing system | TN-S IT TT |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Reset | Manual reset |
| Test function | Local Remote test |
|---|---|
| Monitoring | Electronics (continuous) Power supply (continuous) Relay/sensor link (continuous) |
| Type of measurement | Earth fault current internal measurement, range: 80...100 % |
| Tamperproof of settings | Protected by sealable cover |
| Connections - terminals | Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Fault: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Fault: screw terminal cable(s) 0.2…4 mm² rigid AWG 24...AWG 12 Fault: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Relay test and fault reset: screw terminal cable(s) 0.14…1 mm² flexible AWG 26...AWG 16 Relay test and fault reset: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26...AWG 16 Relay test and fault reset: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.14…1 mm² flexible AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26...AWG 16 Sensor: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26...AWG 16 Voltage presence: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Voltage presence: screw terminal cable(s) 0.2…4 mm² rigid AWG 24...AWG 12 Voltage presence: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 |
| Wire stripping length | Auxiliary power supply: 7 mm for top connection Fault: 8 mm for bottom connection Relay test and fault reset: 5 mm for bottom connection Sensor: 5 mm for top connection Voltage presence: 8 mm for bottom connection |
| Tightening torque | Auxiliary power supply: 0.6 N.m top Fault: 0.6 N.m bottom Relay test and fault reset: 0.25 N.m bottom Sensor: 0.25 N.m top Voltage presence: 0.6 N.m bottom |
| 9 mm pitches | 6 |
| Standards | EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144 |
| Width | 54 mm |
| height | 81 mm |
| Depth | 74 mm |
| Net weight | 0.3 kg |
| IP degree of protection | IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Mechanical robustness | Fire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 Vibrations 13.2...100 Hz: 0.7 g Vibrations 2...13.2 Hz: +/- 1 mm |
| Overvoltage category | IV |
|---|---|
| Electrical shock protection class | Class II |
| Electromagnetic compatibility | Conducted and radiated emissions: , B, conforming to CISPR 11 Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 Radiated susceptibility: , 3, conforming to IEC 61000-4-3 |
| Relative humidity | 95 % at 55 °C |
| Pollution degree | 3 conforming to IEC 60664-1 |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -55…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.0 cm |
| Package 1 Width | 8.6 cm |
| Package 1 Length | 9.0 cm |
| Package 1 Weight | 274.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 10.351 kg |
| Warranty | 12 months |
|---|
Main Document
Main Document
Data Sheet : Download56130
Main Document
Data Sheet : Download56130
Reviews (0)
Recommended for you
-
0
Schneider 56163 | Earth-leakage relay RH21M – 300 mA – 0.06 s – 240 V
-
0
Schneider 50441 | closed toroid A type, for Vigirex and Vigilhom, SA200, inner diameter 200 mm, rated current 400 A
-
0
Schneider 50439 | Closed toroid for residual current protection IA – Ø 80 mm
-
0
Schneider 50438 | closed toroid A type, for Vigirex and Vigilhom, PA50, inner diameter 50 mm, rated current 85 A
-
0
Reviews
There are no reviews yet.