Schneider C10B6TM063 Compact | Circuit breaker, ComPacT NSX100B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 63A
Schneider C10B6TM063 Compact
Description
Schneider C10B6TM063 Compact
Introduction
Schneider Electric is a global leader in electrical solutions, known for its innovative products and reliable performance. Among its offerings, it circuit breaker stands out for its compact design and efficient functionality. In this article, we’ll explore the features, specifications, and benefits of this versatile circuit breaker.
Understanding the Schneider C10B6TM063 Compact
What is the Schneider C10B6TM063 Compact?
it is a circuit breaker designed to protect electrical circuits from overloads, short circuits, and other electrical faults. Its compact size makes it suitable for installations where space is limited, without compromising on performance or safety.
Key Features and Specifications
Some of the key features of it:
- Compact design: Saves space and simplifies installation.
- High performance: Capable of handling high current loads efficiently.
- Safety features: Includes mechanisms for thermal and magnetic protection to ensure safe operation.
The Importance of Circuit Breakers
What is a Circuit Breaker?
A circuit breaker is an essential safety device in any electrical system, designed to automatically interrupt the flow of electricity when a fault is detected. This helps prevent damage to the system and reduces the risk of electrical hazards such as fires or equipment damage.
Role in Electrical Safety
Circuit breakers play a crucial role in maintaining electrical safety by:
- Preventing overloads: They interrupt the flow of excessive current to prevent overheating and damage to wiring and equipment.
- Protecting against short circuits: They quickly disconnect the circuit in the event of a short circuit, minimizing damage and risk.
Detailed Features of the C10B6TM063
Compact Design
it design makes it ideal for installations where space is limited, such as in electrical panels or distribution boards.
Performance Capabilities
Despite its small size, the C10B6TM063 is capable of handling high current loads efficiently, ensuring reliable protection for electrical systems.
Safety Features
This circuit breaker is equipped with advanced safety features, including thermal and magnetic protection mechanisms, to ensure safe and reliable operation under various conditions.
Technical Specifications
Electrical Ratings
- Rated current: Up to 63A
- Breaking capacity: High breaking capacity suitable for a wide range of applications
Mechanical Endurance
The C10B6TM063 is built to last, with high mechanical endurance to withstand frequent operation.
Environmental Conditions
It is suitable for use in various environmental conditions, making it versatile for both indoor and outdoor applications.
Applications of the C10B6TM063 Compact
Industrial Use
In industrial settings, the C10B6TM063 provides reliable protection for machinery and equipment, helping to minimize downtime and ensure safety.
Commercial Use
For commercial buildings, this circuit breaker ensures the safety and reliability of essential electrical systems such as lighting, heating, and air conditioning.
Residential Use
In residential applications, the C10B6TM063 protects household electrical systems and appliances from potential hazards, providing peace of mind for homeowners.
Installation and Setup
Step-by-Step Installation Guide
- Turn off the main power supply.
- Mount the circuit breaker in the designated panel.
- Connect the input and output wires securely.
- Ensure all connections are tight and secure.
- Turn on the power and test the circuit breaker.
Important Considerations During Installation
- Follow manufacturer guidelines: Adhere to the installation instructions provided by Schneider Electric.
- Check connections: Ensure all electrical connections are properly secured to prevent faults.
Maintenance and Troubleshooting
Routine Maintenance Tips
- Regular inspections: Periodically inspect the circuit breaker for signs of wear or damage.
- Cleaning: Keep the breaker and its surroundings clean to prevent dust buildup.
Common Issues and How to Fix Them
- Frequent tripping: This may indicate an overload or fault in the circuit. Check the load distribution and inspect for any faults.
- Loose connections: Ensure all connections are tight and secure.
Comparing the C10B6TM063 to Other Models
Comparison with Other Schneider Models
The C10B6TM063 offers a balance of performance, reliability, and affordability compared to other Schneider models in its range.
Comparison with Competitor Products
Compared to competitor products, the C10B6TM063 often provides superior performance and safety features, making it a preferred choice for many users.
Benefits of Using Schneider C10B6TM063 Compact
Enhanced Safety
The C10B6TM063’s advanced safety features provide maximum protection for electrical systems, minimizing the risk of accidents or damage.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100B |
| Product or component typee | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 8.61 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 63 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 500 A |
| earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.5 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19 cm |
| Package 1 Weight | 2.307 kg |
| Unit Type of Package 2 | CAR |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 23 cm |
| Package 2 Width | 39 cm |
| Package 2 Length | 49 cm |
| Package 2 Weight | 14.7275 kg |
| Unit Type of Package 3 | PAL |
| Number of Units in Package 3 | 48 |
| Package 3 Height | 107 cm |
| Package 3 Width | 40 cm |
| Package 3 Length | 60 cm |
| Package 3 Weight | 122.82 kg |
Reviews