Description

Schneider EZC100N3015 | circuit breaker Easypact EZC100N – TMD – 15 A – 3 poles 3d

The Schneider EZC100N3015 is a molded case circuit breaker (MCCB) from the EasyPact EZC100N series, designed for effective protection and control of low-voltage electrical installations. With a 15 A current rating, this unit features a TMD (Thermal Magnetic) trip unit, offering dependable overload and short-circuit protection.

 Technical Specifications

  • Product Model: EZC100N3015

  • Series: EasyPact EZC100N

  • Rated Current (In): 15 A

  • Number of Poles: 3 (3P)

  • Connection Type: 3D (Three-pole direct connection)

  • Trip Unit: TMD (Thermal-Magnetic, fixed settings)

  • Rated Insulation Voltage (Ui): 690 V AC

  • Rated Operational Voltage (Ue): Up to 415 V AC

  • Ultimate Breaking Capacity (Icu):

    • Up to 25 kA at 415 V AC

  • Utilization Category: A

  • Standard Compliance: IEC 60947-2

  • Mounting: Fixed

 Key Features

  • Thermal-magnetic trip unit

    • Protects against both overloads and short circuits

  • Compact and Robust

    • Ideal for space-limited panels and reliable in tough environments

  • Easy to Install

    • Direct mounting and wiring with standard terminal connections

  • Cost-effective Protection

    • Optimized for budget-sensitive applications without compromising safety

 Applications

  • Distribution boards

  • Motor protection and control

  • Light industrial and commercial installations

  • HVAC units and building infrastructure

  • Backup generator connections

The Schneider EZC100N3015 provides a compact, reliable, and economical solution for low current protection in 3-phase systems. Its robust construction and straightforward installation make it ideal for a wide range of electrical distribution needs.

Additional information

brands

Schneider Electric

Specifications

Main
Range of product EasyPact
Product or component type Circuit breaker
Device short name Easypact EZC100N
circuit breaker name Easypact EZC100N
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type DC AC
Network frequency 50/60 Hz
[In] rated current 15 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Breaking capacity code N
Breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 15 A at 50 °C
Protection type Short-circuit protection Overload protection
Pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Complementary
control type Toggle
Mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Mechanical durability 8500 cycles
Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 25 mm
local signalling Positive contact indication
Neutral protection setting Without protection
earth-leakage protection Without
height 130 mm
Width 75 mm
Depth 60 mm
Environment
Standards JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -35…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.5 cm
Package 1 Width 14.0 cm
Package 1 Length 8.0 cm
Package 1 Weight 790.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 12
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 9.935 kg
Unit Type of Package 3 P12
Number of Units in Package 3 192
Package 3 Height 50.0 cm
Package 3 Width 80.0 cm
Package 3 Length 120.0 cm
Package 3 Weight 167.576 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider EZC100N3015 | circuit breaker Easypact EZC100N – TMD – 15 A – 3 poles 3d”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare