Schneider GVAE11 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC
Schneider GVAE11 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC
Description
Schneider GVAE11 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC
The Schneider Electric GVAE11 is an auxiliary contact block designed for use with TeSys GV2 and GV3 motor circuit breakers. It provides one normally open (1 NO) and one normally closed (1 NC) contact, enabling remote signaling of the circuit breaker status (ON/OFF or TRIP). It is ideal for control and monitoring applications in industrial automation.
Key Benefits:
-
Quick Mounting: Easy front snap-on assembly without tools
-
Compact Design: Saves space inside panels
-
Dual Functionality: Provides both open and closed contact states for versatile control logic
-
Reliable Performance: Built for industrial environments with frequent operation cycles
Typical Applications:
-
Status indication of motor circuit breakers
-
Integration into control panels and PLC systems
-
Signaling for remote monitoring and safety interlocks
-
Industrial machinery, HVAC systems, pump stations
-
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on front side of the circuit breaker, connection by screw clamp terminals. Sold in lots of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys TeSys Deca |
|---|---|
| Device short name | GVAE |
| Product or component type | Auxiliary contact block |
| Product compatibility | GV2P GV2RT GV2ME GV3L GV2LE GV3P GV2L |
| Mounting location | Front side |
| Pole contact composition | 1 NO + 1 NC |
| Quantity per set | Set of 10 |
| [Ui] rated insulation voltage | 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1 |
|---|---|
| [Ue] rated operational voltage | 24...240 V AC 24...60 V DC |
| [Ith] conventional free air thermal current | 2.5 A |
| Mechanical durability | 100000 cycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Protection type | GG fuse 10 A GB2CB06 circuit breaker 10 A |
| Rated operational power in VA | 120 VA at 110…120 V AC-15 - electrical durability: 100000 cycles 120 VA at 230…240 V AC-15 - electrical durability: 100000 cycles 48 VA at 24 V AC-15 - electrical durability: 100000 cycles 60 VA at 48 V AC-15 - electrical durability: 100000 cycles |
| Rated operational power in W | 15 W at 48 V DC-13 - electrical durability: 100000 cycles 24 W at 24 V DC-13 - electrical durability: 100000 cycles 9 W at 60 V DC-13 - electrical durability: 100000 cycles |
| Tightening torque | 1.4 N.m - on screw clamp terminals |
| height | 11 mm |
| Width | 45 mm |
| Depth | 29 mm |
| Net weight | 0.02 kg |
| Environmental characteristic | Normal environment |
|---|---|
| product certifications | UKCA |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.200 cm |
| Package 1 Width | 6.000 cm |
| Package 1 Length | 7.000 cm |
| Package 1 Weight | 17.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 6.200 cm |
| Package 2 Width | 12.000 cm |
| Package 2 Length | 7.400 cm |
| Package 2 Weight | 174.000 g |
| Unit Type of Package 3 | S02 |
| Number of Units in Package 3 | 220 |
| Package 3 Height | 15.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 4.123 kg |
| Warranty | 18 months |
|---|