Schneider METSEPM1225HCL1 | panel mount meter EasyLogic PM1225H, class 1, RS485, LCD
Schneider METSEPM1225HCL1 | panel mount meter EasyLogic PM1225H, class 1, RS485, LCD
Description
Schneider METSEPM1225HCL1 | panel mount meter EasyLogic PM1225H, class 1, RS485, LCD
. Technical Specifications
-
Manufacturer: Schneider Electric
-
Product Series: EasyLogic PM1200
-
Model Number: METSEPM1225HCL1
-
Meter Type: Digital panel-mount energy meter
-
Accuracy Class: Class 1 (per IEC 62053-21 for active energy)
-
Measurement Type: True RMS, 3-phase or single-phase
-
Rated Voltage Input:
-
Up to 480 V AC (line-to-line)
-
-
Current Input:
-
Via external current transformers (CTs) – 5 A nominal
-
-
Frequency: 50/60 Hz
-
Display: Backlit LCD (7-segment, 3 lines)
-
Communication Interface: RS-485 port
-
Protocol Supported: Modbus RTU
-
Mounting Type: Panel-mounted (DIN 96 x 96 mm cutout)
-
Power Supply:
-
Auxiliary voltage: 80 to 300 V AC / 90 to 300 V DC
-
-
Compliance: IEC 62053-21, IEC 61010-1, RoHS
. Key Features
-
High-visibility LCD for easy local reading of all key electrical values
-
Class 1 accuracy for active energy measurements
-
RS-485 Modbus RTU for easy integration into BMS or SCADA systems
-
Compact and modular design for ease of installation in panels
-
Measures:
-
Voltage (phase & line)
-
Current (per phase and total)
-
Active, reactive & apparent power
-
Power factor and frequency
-
Energy (kWh, kvarh, kVAh)
-
-
Configurable CT/PT ratio settings
-
Password protection for setup parameters
. Typical Applications
The EasyLogic PM1225H is widely used for:
-
Electrical distribution panels (main or sub-metering)
-
Commercial buildings and shopping centers
-
Industrial automation systems
-
Backup power and generator monitoring
-
Energy audits and load profiling
-
Tenant metering and energy cost allocation
. Advantages
-
Cost-effective metering solution with essential features
-
Reliable and accurate measurements in Class 1 applications
-
Easy installation with standard DIN cutout and terminal labeling
-
Integrated communication for remote monitoring and data logging
-
Designed and tested to Schneider Electric’s global quality standards
-
Expandable with accessories such as communication gateways and displays
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyLogic |
|---|---|
| Product or component type | Energy meter |
| Power quality analysis | total harmonic distortion |
|---|---|
| Device application | Energy monitoring |
| Type of measurement | Current Voltage Frequency Power factor Phase angle RPM Peak demand power Harmonic distorsion (I THD & U THD) Active power Active energy |
| Metering type | Average current Iavg Phase currents Active power P, P1, P2, P3 Active, reactive, apparent energy (signed, four quadrant) Rotation speed Average voltage Vavg Calculated neutral current Unbalance current Apparent power S, S1, S2, S3 Unbalance voltage Frequency Voltage U21, U32, U13, V1, V2, V3 Demand power P, Q, S Reactive power Q, Q1, Q2, Q3 Power factor and displacement PF (signed, four quadrant) Phase current I1, I2, I3 RMS |
| Counter functions | ON hour counting ON-load hour counting Power interruption |
| [Us] rated supply voltage | 48...277 V AC/DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 1 A 5 A |
| type of network | 3P 2P + N 1P + N 3P + N 2P |
| Maximum power consumption in VA | 4 VA at 240 V |
| Maximum power consumption in W | 2 W at 240 V |
| Display type | LCD display |
| Display colour | Monochrome |
| Display digits | 12 digit(s) |
| Communication of data | Reading of measurements All counters Revolution speed Last cleared log Instantaneous and demand values |
| Tamperproof of settings | Protected by access code |
| Sampling rate | 32 samples/cycle |
| Measurement current | 5…6000 mA |
| Signal | Voltage (impedance 5 MOhm)4 x Current 0.005...10 A (impedance 0.3 MOhm)6 x |
| Measurement voltage | 46…277 V AC 50...60 Hz between phase and neutral 80…480 V AC 50...60 Hz between phases 277…999000 V AC 50...60 Hz with external VT |
| Frequency measurement range | 45…65 Hz |
| Measurement accuracy | Current +/- 0.5 % Voltage +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.01 Reactive power +/- 2 % Active power +/- 1 % Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 2 % Apparent energy +/- 1 % Harmonic distorsion (I THD & U THD) +/- 5 % |
| Accuracy class | Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 |
| Demand intervals | 1 s |
| Local signalling | Green LED: activity Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) LED: voltage indication |
| Communication port protocol | Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V |
| Communication port support | Screw connector: RS485 |
| Data recording | Energy consumption logs |
| Material | Polycarbonate |
| Flame retardance | V-0 conforming to UL 94 |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Provided equipment | Installation guide |
| Installation category | III |
| Type of installation | Indoor installation |
| Measurement category | Category III 480 V |
| Electrical insulation class | Class II |
| Connections - terminals | Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s) |
| Tightening torque | Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver Communication: 0.5…0.6 N.m Philips no 1 screwdriver |
| Wire stripping length | Current circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm 7 mm |
| Standards | IEC 61010-1:ed. 3 UL 61010-1:ed. 3 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 C-Tick |
| Width | 96 mm |
| Depth | Outside : 13 mm Panel : 49 mm |
| Height | 96 mm |
| Net weight | 300 g |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A Emission tests conforming to FCC part 15 Subpart C Emission tests conforming to FCC part 15 Subpart E |
|---|---|
| Overvoltage category | III |
| IP degree of protection | IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C |
| Pollution degree | 2 |
| Ambient air temperature for operation | -10…60 °C |
| Ambient air temperature for storage | -20…70 °C |
| Operating altitude | <= 2000 m |
| Service life | 7 year(s) |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.88 cm |
| Package 1 Width | 9.6 cm |
| Package 1 Length | 9.6 cm |
| Package 1 Weight | 350.0 g |
Reviews