Schneider A9F77206 | Miniature circuit-breaker, Acti9 iC60N, 2P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Schneider A9F77206 | Miniature circuit-breaker, Acti9 iC60N, 2P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Description
Schneider A9F77206 | Miniature circuit-breaker, Acti9 iC60N, 2P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Technical Specifications
-
Product Model: A9F77206
-
Series: Acti9 iC60N
-
Type: Miniature Circuit Breaker (MCB)
-
Number of Poles: 2P (simultaneous switching and protection of phase and neutral)
-
Rated Current: 6 A
-
Tripping Curve: C Curve (trips between 5 to 10 times the rated current)
-
Rated Voltage: 230/400 V AC
-
Breaking Capacity:
-
6000 A according to IEC 60898-1
-
10,000 A according to IEC 60947-2
-
-
Rated Frequency: 50/60 Hz
-
Mounting: DIN rail (modular)
-
Terminal Type: Tunnel terminals for safe and secure connections
-
Connection Capacity:
-
Rigid wire: 1.5–25 mm²
-
Flexible wire: 1.5–16 mm²
-
-
IP Protection: IP20 (up to IP40 when installed in enclosure)
-
Dimensions (H x W x D): Approx. 85 x 36 x 78.5 mm
-
Operating Temperature: -25°C to +70°C
-
Standards: IEC 60898-1 and IEC 60947-2
-
Certifications: CE, EAC, and other international approvals
Key Features
The Schneider A9F77206 is engineered with both safety and durability in mind. Its C curve tripping characteristic makes it well-suited for general-purpose loads with low to moderate inrush currents, such as lighting systems, small appliances, and control panels. The dual-pole configuration provides simultaneous disconnection of both the phase and neutral conductors, enhancing operational safety and simplifying maintenance.
Its modular design allows easy integration into standard DIN rail distribution boards and switchboards. It also includes VisiTrip and VisiSafe indicators (available on iC60N range), which help with fast fault diagnosis and safer maintenance operations.
With a mechanical life of up to 20,000 operations and an electrical life of up to 10,000 operations, this MCB offers long-term reliability in demanding environments.
Applications
-
Lighting Circuits: Suitable for indoor and outdoor lighting circuits in residential and commercial buildings.
-
Control Circuits: Often used to protect low-power control systems and automation circuits in industrial panels.
-
Socket Circuits: Ideal for protecting general-purpose socket outlets in light-load environments.
-
Small Motors & Devices: Provides safe protection for equipment with modest inrush currents.
-
Residential Distribution Boards: A common choice for main or sub-circuit protection in homes and apartments.
-
IT and Data Centers: Used for protecting sensitive circuits and ensuring continuity of supply to critical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 6 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 EN 60947-2 IEC 60947-2 IEC 60898-1 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | Trip indicator |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| net weight | 0.25 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.3 cm |
| Package 1 Width | 3.6 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 217 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8.6 cm |
| Package 2 Width | 10 cm |
| Package 2 Length | 22.4 cm |
| Package 2 Weight | 1.362 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 15.55 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F77206
Main Document
Data Sheet : A9F77206
Reviews (0)
Recommended for you
Schneider A9N61515 | miniature circuit breaker – C60H – 1 pole – 32 A – C curve
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
Schneider A9N61502 | miniature circuit breaker – C60H – 1 pole – 2 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0
Reviews
There are no reviews yet.