Schneider A9R41240 | Acti 9 iID – RCCB – 2P – 40A – 30mA – type AC

Technical Specifications A9R41240

  • Product Type: Residual Current Circuit Breaker (RCCB)

  • Series: Acti 9 iID

  • Model Number: A9R41240

  • Number of Poles: 2P (Line + Neutral)

  • Rated Current (In): 40 A

  • Residual Operating Current (IΔn): 30 mA

  • Type of Protection: Type AC (detects sinusoidal AC residual currents)

  • Rated Voltage: 230 V AC ±10%

  • Frequency: 50/60 Hz

  • Insulation Voltage: 500 V

  • Short-Circuit Withstand Capacity (conditional): 10 kA (with upstream protection)

  • Endurance:

    • Mechanical: 20,000 operations

    • Electrical: 10,000 operations

  • Mounting: DIN rail (35 mm)

  • Terminal Capacity:

    • Rigid: 1.5 – 25 mm²

    • Flexible: 1.5 – 16 mm²

  • IP Degree of Protection: IP20 (IP40 when installed in an enclosure)

  • Operating Temperature: -25°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Standards Compliance:

    • IEC 61008-1

    • IEC 61008-2-1

  • Certifications: CE, VDE, EAC

Key Features

  • Earth Leakage Protection: Disconnects the power supply in case of ground faults to prevent electric shock and fire hazards.

  • 30 mA Sensitivity: Offers personal protection by rapidly detecting low-level leakage currents.

  • Type AC Sensitivity: Suitable for detecting sinusoidal AC residual currents, ideal for most standard residential circuits.

  • Compact and Modular Design: Saves space in distribution boards and integrates seamlessly with Acti 9 accessories.

  • High Reliability: Long mechanical and electrical life with robust internal components.

  • User-Friendly Operation: Clear ON/OFF status indication, test button for regular functionality checks.

  • Safe Terminals: Finger-safe design with IP20 protection rating ensures secure wiring and safety during maintenance.

Applications

The A9R41240 RCCB is ideally suited for use in:

  • Residential Homes and Apartments: Protection of lighting, socket, and general-purpose circuits

  • Small Commercial Buildings: Office spaces, shops, and retail units

  • Wet Zones: Kitchens, bathrooms, laundries (where personal protection is crucial)

  • Distribution Boards: Installed in main or sub-distribution panels

  • Educational and Healthcare Facilities: For enhanced safety where people are in contact with electrical equipment

Additional information

brands

Schneider Electric

Specifications

Main
Range Acti9
Product name Acti9 iID
product or component type Residual current circuit breaker (RCCB)
Device short name iID
Poles description 2P
Neutral position Left
[In] rated current 40 A
Network type AC
Earth-leakage sensitivity 30 mA
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Complementary
Device location in system Outgoer
Network frequency 50/60 Hz
[Ue] rated operational voltage 220...240 V AC 50/60 Hz
Residual current tripping technology Voltage independent
Rated breaking and making capacity Idm 1500 A Im 1500 A
Rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Surge current 250 A
Contact position indicator Yes
Control type Toggle
Mounting mode Clip-on
Mounting support DIN rail
9 mm pitches 4
Height 91 mm
Width 36 mm
Depth 73.5 mm
net weight 0.21 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability AC-1: 15000 cycles
Locking options description Padlocking device
Connections - terminals Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Environment
Standards EN/IEC 61008-1 EN/IEC 61008-2-1
IP degree of protection IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree 3
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation -5…60 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.000 cm
Package 1 Width 8.500 cm
Package 1 Length 10.000 cm
Package 1 Weight 210.700 g
Unit Type of Package 2 S03
Number of Units in Package 2 54
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 11.773 kg
Unit Type of Package 3 P12
Number of Units in Package 3 432
Package 3 Height 45.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 106.198 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider A9R41240 | Acti 9 iID – RCCB – 2P – 40A – 30mA – type AC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare