Schneider G12F3A100 |Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
Schneider G12F3A100 |Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
Description
Schneider G12F3A100 |Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
Technical Specifications G12F3A100
-
Product Name: Schneider Electric G12F3A100
-
Product Type: Molded Case Circuit Breaker (MCCB)
-
Series: GoPact MCCB 125
-
Number of Poles: 3 poles
-
Rated Current (In): 100 Amps
-
Frame Size: 125 A
-
Rated Operational Voltage (Ue): Up to 415 VAC
-
Breaking Capacity (Icu): 30 kA at 415 VAC
-
Trip Unit Type: TMD (Thermal Magnetic Trip Unit)
-
Thermal Trip: Adjustable – allows fine-tuning to protect against overloads
-
Magnetic Trip: Fixed – fast response to short-circuit faults
-
Frequency: 50/60 Hz
-
Mounting Type: Fixed mounting (standard for panelboards)
-
Compliance: IEC 60947-2
-
Utilization Category: AC-22A — general-purpose protection for mixed resistive and inductive loads
Key Features G12F3A100
-
High-Performance Protection
Rated at 100A with a high breaking capacity of 30 kA, this MCCB is ideal for demanding applications requiring strong fault-clearing ability. -
Adjustable Thermal Overload Protection
Offers flexibility to match system load requirements, improving selectivity and minimizing nuisance tripping. -
Fixed Magnetic Protection
Ensures rapid disconnection during high short-circuit conditions, enhancing safety and protecting downstream equipment. -
Enhanced Safety and Durability
Engineered for reliable long-term operation even in harsh industrial environments, thanks to Schneider Electric’s quality design. -
Compact & Easy to Install
Standardized dimensions and front access terminals streamline installation in new or existing panel setups. -
Schneider Electric Assurance
Backed by a globally recognized brand known for electrical safety, innovation, and compliance.
Applications
-
Industrial Facilities & Heavy Equipment
Provides critical protection for high-demand systems including motors, drives, and heavy machinery. -
Large Commercial Buildings
Used in main or sub-distribution panels to supply power to large HVAC systems, elevators, and lighting systems. -
Renewable Energy Plants
Suitable for inverter protection, main feeders, and other circuits where higher fault levels may occur. -
Critical Infrastructure
Trusted for power distribution in hospitals, airports, water treatment plants, and data centers. -
Backup & Emergency Power
Ideal for protecting generator outputs and large UPS systems in emergency power applications. -
Construction Sites & Temporary Installations
Provides strong protection in temporary power distribution boards where high fault currents may occur.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 125 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | F 30 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 8000 cycles at 415 V In |
| Power dissipation per pole | 18.7 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 25 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.8...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 10 x In |
| Width (W) | 75 mm |
| Height (H) | 130 mm |
| Depth (D) | 60 mm |
| net weight | 0.7 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.4 cm |
| Package 1 Width | 8.5 cm |
| Package 1 Length | 13.9 cm |
| Package 1 Weight | 908 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.579 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 128 |
| Package 3 Height | 75 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 129.764 kg |
Main Document
Main Document
Data Sheet : G12F3A100
Main Document
Data Sheet : G12F3A100
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18469 | Miniature circuit-breaker, Acti9 C120H, 3P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9K24163 | Miniature circuit-breaker, Acti9 iK60N, 1P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9F94463 | Miniature circuit-breaker, Acti9 iC60L, 4P, 63 A, C curve, 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.