Schneider C12N3TM160L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 3 poles, TMD trip unit 160A, EverLink lugs
Schneider C12N3TM160L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 3 poles, TMD trip unit 160A, EverLink lugs
Description
Schneider C12N3TM160L: Exploring Its Features and Applications
Introduction
The Schneider C12N3TM160L is a prominent offering from Schneider Electric, designed to meet the demands of modern electrical systems with its robust features and reliable performance. This article delves into its specifications, key features, applications across various sectors, installation guidelines, and more.
Key Specifications
Power Rating and Voltage
it operates at [specify power rating] and [voltage details], ensuring compatibility with a wide range of electrical applications.
Dimensions and Design
With dimensions of [specify dimensions], the device is engineered to be compact yet durable, suitable for diverse installation environments.
Environmental Considerations
It is designed to operate efficiently in [mention environmental conditions], ensuring longevity and reliability.
Features and Benefits
Advanced Protection Features
Equipped with [list advanced protection features], it ensures enhanced safety and protection for connected equipment.
High Efficiency
It boasts [highlight efficiency features], optimizing energy consumption and reducing operational costs.
User-Friendly Interface
Featuring [describe user interface features], the device offers intuitive operation and simplified maintenance.
Applications
Industrial Applications
In industrial settings, it excels in [list industrial applications], providing reliable electrical distribution and protection.
Commercial Applications
For commercial installations, such as [mention commercial settings], it offers efficient power management and safety.
Residential Applications
Even in residential environments, homeowners benefit from [describe residential applications], ensuring safe and efficient electricity distribution.
Installation and Maintenance
Installation Requirements
Installing it involves [outline installation requirements], ensuring compliance with industry standards and safety regulations.
Maintenance Tips
Regular maintenance includes [mention maintenance tasks], which help enhance longevity and optimize performance.
Warranty and Support
Warranty Coverage
The product is supported by [specify warranty details], providing assurance to customers.
Customer Support
Schneider Electric offers [describe customer support options], ensuring prompt assistance and technical guidance.
Conclusion
The Schneider C12N3TM160L exemplifies Schneider Electric’s commitment to delivering reliable and efficient electrical solutions. With its advanced features, robust design, and versatility across industrial, commercial, and residential sectors, it remains a preferred choice for professionals seeking dependable electrical distribution and protection.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160N |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 160 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 12.21 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…70 mm², flexible copper 1 Everlink lug wire size 2.5…95 mm², rigid or stranded copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 160 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1250 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 8.8 cm |
| Package 1 Length | 21.0 cm |
| Package 1 Weight | 1.202 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.202 kg |
Reviews
There are no reviews yet.