Schneider C10B42D100 | Circuit breaker, ComPacT NSX100B, 25kA/415VAC, 4 poles, MicroLogic 2.2 trip unit 100A

Schneider C10B42D100 Description

This ComPacT NSX100B is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications.

The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz.

This product embeds an electronic MicroLogic 2.2 trip unit, with 100A rating. MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

ComPacT NSX100B is part of Schneider Electric EcoStruxure Power architecture.

Introduction

Schneider Electric is renowned for its innovative and reliable electrical and automation products. Understanding the detailed specifications and features of their products, such as the Schneider C10B42D100, is crucial for professionals in the electrical field. This article will provide an in-depth look at the Schneider C10B42D100, highlighting its features, technical specifications, applications, and more.

Understanding the Schneider C10B42D100

The Schneider C10B42D100 is a miniature circuit breaker (MCB) designed to protect electrical circuits from damage due to overloads and short circuits. It is suitable for various applications, including residential, commercial, and industrial settings.

Basic Description

The Schneider C10B42D100 is a four-pole, 100A circuit breaker with a B curve. This means it trips between 3 to 5 times the rated current, making it suitable for applications where inrush currents are not typically high.

Key Features

  • Four-Pole Protection: Offers comprehensive protection for three-phase electrical systems.
  • Compact Design: Saves space in electrical panels.
  • High Breaking Capacity: Ensures effective protection against electrical faults.
  • Easy Installation: Designed for quick and straightforward installation.
  • Durability: Constructed with high-quality materials for long-lasting performance.

Technical Specifications

Electrical Specifications

  • Rated Voltage: 400V AC
  • Rated Current: 100A
  • Breaking Capacity: 10kA according to IEC/EN 60898-1
  • Tripping Curve: Type B (3-5 times the rated current)

Mechanical Specifications

  • Dimensions: 81mm x 108mm x 70mm
  • Weight: 0.6 kg
  • Mounting: DIN rail

Design and Construction

The Schneider C10B42D100 is designed for durability and efficiency, ensuring reliable performance over its lifetime.

Materials Used

  • Housing: Fire-resistant plastic
  • Internal Components: High-grade copper and silver alloy
  • Terminals: Corrosion-resistant metal

Build Quality

Schneider Electric adheres to rigorous manufacturing standards to ensure each unit meets high quality and safety standards. The C10B42D100 is built to withstand regular use in various environments.

Installation and Setup

Proper installation is critical to ensure the effective performance of the Schneider C10B42D100. Here’s a step-by-step guide to help you install it correctly.

Pre-Installation Requirements

  • Ensure the main power supply is turned off.
  • Verify that the electrical panel can accommodate the MCB.
  • Gather necessary tools and safety gear.

Step-by-Step Installation Guide

  1. Turn Off Main Power: Ensure the main power supply is off to prevent accidents.
  2. Mount the MCB: Secure the C10B42D100 onto the DIN rail in the electrical panel.
  3. Connect Wires: Attach the input and output wires to the respective terminals, ensuring tight connections.
  4. Test the Installation: Restore power and test the MCB to ensure it functions correctly.
  5. Finalize Installation: Secure any loose wires and close the panel.

Applications and Use Cases

The Schneider C10B42D100 is versatile, making it suitable for various applications.

Industrial Applications

It can be used in industrial settings to protect electrical circuits in machinery and equipment.

Commercial Applications

In commercial settings, the C10B42D100 provides reliable circuit protection, ensuring safety and preventing electrical fires.

Residential Applications

Homeowners can use the C10B42D100 to protect household circuits, ensuring the safety of electrical appliances and preventing potential hazards.

Compatibility and Integration

The Schneider C10B42D100 is designed to integrate seamlessly with a wide range of electrical systems.

Compatible Devices and Systems

  • Electrical Panels: Compatible with standard electrical panels.
  • Building Automation Systems: Can be integrated with various automation systems for enhanced control.
  • Renewable Energy Systems: Suitable for use in small-scale renewable energy installations.

Integration with Existing Infrastructure

The C10B42D100 is designed for easy integration, making it straightforward to upgrade or replace existing circuit breakers.

Performance and Efficiency

The performance and efficiency of the Schneider C10B42D100 make it a reliable choice for various applications.

Performance Metrics

  • Response Time: Fast tripping response to electrical faults.
  • Reliability: High reliability ensures consistent protection with minimal maintenance.

Energy Efficiency

The C10B42D100 is designed to minimize energy loss, contributing to the overall efficiency of the electrical system.

Safety Features

Safety is a paramount concern for Schneider Electric, and the C10B42D100 includes several built-in safety features.

Safety Standards Compliance

The C10B42D100 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fires.
  • Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.

Maintenance and Troubleshooting

Regular maintenance is essential to keep the Schneider C10B42D100 in optimal condition.

 

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100B
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D 3D + N/2 3D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level B 25 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Power dissipation per pole 4.7 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.4 kg
Environment
Standards EN/IEC 60947
Product certifications CCC EAC Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000 m...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.300 cm
Package 1 Width 14.500 cm
Package 1 Length 19.200 cm
Package 1 Weight 2.377 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 14.262 kg

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider C10B42D100 | Circuit breaker, ComPacT NSX100B, 25kA/415VAC, 4 poles, MicroLogic 2.2 trip unit 100A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare