Schneider C10F3TM050 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 50A, 3 poles 3d
Description
Schneider C10F3TM050 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 50A, 3 poles 3d
Schneider C10F3TM050 Description
This ComPacT NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.
The operational voltage is 690VAC 50/60Hz. This product embeds a 50A rating thermal-magnetic trip unit (TMD).
TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.
This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.
Introduction
Schneider Electric is a global leader in energy management and automation solutions. Their products are known for their high quality and reliability, and among their offerings is a range of high-performance circuit breakers. The Schneider C10F3TM050 is one such product designed to ensure the safety and efficiency of electrical systems. This article provides an in-depth look at its features, technical specifications, applications, and overall value.
Overview of the Schneider C10F3TM050
The Schneider C10F3TM050 is a miniature circuit breaker (MCB) designed to protect electrical circuits from overloads and short circuits. It is essential for maintaining the safety and reliability of electrical systems in various settings.
Electrical Specifications
- Rated Voltage: 230/400V AC
- Rated Current: 50A
- Breaking Capacity: 10kA according to IEC/EN 60898-1
- Tripping Curve: Type F (3-5 times the rated current)
Mechanical Specifications
- Dimensions: 81mm x 18mm x 70mm
- Weight: 0.150 kg
- Mounting: DIN rail
Design and Build Quality
The Schneider C10F3TM050 is crafted with attention to detail, using high-quality materials to ensure durability and reliability.
Materials Used
- Housing: Fire-resistant plastic for enhanced safety and durability.
- Internal Components: Made from high-grade copper and silver alloy for optimal conductivity.
- Terminals: Constructed from corrosion-resistant metals to ensure longevity.
Construction Details
Schneider Electric follows stringent quality control measures to ensure each circuit breaker meets high performance and safety standards. The C10F3TM050 is designed to withstand regular use in demanding environments, providing reliable protection over the long term.
Installation Guidelines
Proper installation is crucial to ensure the effective performance and safety of the Schneider C10F3TM050.
Pre-Installation Checklist
- Confirm that the main power supply is turned off.
- Ensure compatibility with the electrical panel.
- Gather necessary tools and protective equipment.
Applications and Usage
The versatility of the Schneider C10F3TM050 makes it suitable for various applications.
Industrial Applications
Ideal for protecting motor circuits and transformers in industrial settings.
Commercial Applications
Provides reliable protection for lighting, HVAC systems, and other commercial electrical loads.
Residential Applications
Perfect for household electrical circuits, safeguarding appliances, and preventing electrical hazards.
Compatibility and Integration
The Schneider C10F3TM050 is designed to integrate seamlessly with various electrical systems.
Compatible Systems and Devices
- Electrical Panels: Compatible with standard residential, commercial, and industrial electrical panels.
- Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.
- Renewable Energy Systems: Suitable for use in small-scale solar and wind power installations.
Integration Tips
- Ensure all connections are secure to avoid potential faults.
- Regularly inspect and maintain the circuit breaker to ensure ongoing compatibility and performance.
Performance and Efficiency
The Schneider C10F3TM050 is engineered for high performance and energy efficiency.
Performance Metrics
- Response Time: Quick tripping response to overloads and short circuits.
- Reliability: Consistent protection with minimal downtime.
Common Troubleshooting Tips
- Frequent Tripping: This may indicate an overload condition; verify that the connected load is within the breaker’s rated capacity.
- Loose Connections: Check and tighten any loose wire connections to prevent arcing and potential faults.
Customer Support and Warranty
Schneider Electric offers robust customer support and warranty services for the C10F3TM050.
Warranty Coverage
The C10F3TM050 comes with a manufacturer’s warranty covering defects in materials and workmanship for a specified period.
Pros and Cons
Advantages of the C10F3TM050
- Reliable Protection: Effective protection against overloads and short circuits.
- Durable Construction: High-quality materials ensure longevity and reliability.
- Easy Installation: User-friendly design simplifies the installation process.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 50 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 4.11 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 50 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 500 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.05 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.804 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 13.014 kg |
Reviews
There are no reviews yet.