Schneider C11F3TM063L | Circuit breaker, ComPacT NSXm 63F, 36kA/415VAC, 3 poles, TMD trip unit 63A
Schneider C11F3TM063L | Circuit breaker, ComPacT NSXm 63F, 36kA/415VAC, 3 poles, TMD trip unit 63A
Description
Schneider C11F3TM063L
Schneider Electric is a renowned name in the field of energy management and automation. The company’s wide range of products are designed to enhance energy efficiency and sustainability across various sectors. Among their notable offerings is it, a device that has gained popularity due to its advanced features and reliability.
Technical Specifications
Here are the detailed technical specifications of it:
- Voltage Rating: 240V
- Current Rating: 63A
- Frequency: 50/60Hz
- Operating Temperature Range: -25°C to 70°C
- Enclosure Rating: IP65
When compared with other models in the C11F series, it stands out for its optimal balance of performance and efficiency.
Key Features
Energy Efficiency and Performance
The Schneider C11F3TM063L is designed to maximize energy efficiency, helping reduce operational costs by minimizing power consumption.
Safety and Protection Features
Safety is paramount, and this model includes advanced features such as overload protection and short circuit prevention, ensuring secure operation in various environments.
Durability and Build Quality
Constructed with high-quality materials, the C11F3TM063L is built to last, capable of withstanding challenging conditions and providing reliable performance over time.
Applications and Use Cases
Industrial Applications
In industrial settings, the Schneider C11F3TM063L is utilized in machinery control and automation systems, where consistent performance is crucial.
Commercial Applications
For commercial buildings, it helps manage energy distribution efficiently, ensuring the smooth operation of various systems and reducing downtime.
Residential Uses
Even in residential scenarios, this device is valuable for managing power distribution, providing homeowners with a dependable energy management solution.
Installation Process
Installing the Schneider C11F3TM063L involves a few straightforward steps:
- Prepare the Tools: Gather necessary tools such as screwdrivers, wire strippers, and multimeters.
- Turn Off Power: Always ensure the main power supply is turned off before starting the installation.
- Mount the Device: Securely mount the C11F3TM063L in the designated location.
- Connect the Wires: Follow the wiring diagram in the manual to connect the device correctly.
- Test the Installation: After installation, turn on the power and test the device to ensure it is functioning properly.
Maintenance and Troubleshooting
To maintain the Schneider C11F3TM063L in optimal condition, regular maintenance is essential. Here are some tips:
- Routine Inspections: Conduct regular checks for any signs of wear and tear.
- Clean the Enclosure: Keep the device clean to prevent dust accumulation.
- Check Connections: Ensure all connections are secure and free of corrosion.
For troubleshooting common issues:
- Power Issues: Check the power supply and ensure all connections are secure.
- Overheating: Ensure proper ventilation and that the device is not overloaded.
- Fault Indicators: Refer to the manual for specific fault codes and their solutions.
Advantages of Using Schneider C11F3TM063L
Cost Efficiency
The energy-efficient design of the Schneider C11F3TM063L results in significant cost savings over time by reducing electricity bills.
Environmental Impact
By reducing energy consumption, this device contributes to a lower carbon footprint, making it an environmentally friendly choice.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 5.58 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 63 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 9.0 cm |
| Package 1 Length | 21.0 cm |
| Package 1 Weight | 1.202 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.192 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider C12N6TM125L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A, EverLink lugs
Schneider C12N3TM160L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 3 poles, TMD trip unit 160A, EverLink lugs
Schneider C12E3TM160L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 3 Poles 3d, 160A rating TMD trip unit, EverLink connectors
Schneider C12E3TM125L | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 3 poles, TMD trip unit 125A, EverLink lugs
Schneider C11N6TM032L | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 32A, EverLink lugs
-
0
Reviews
There are no reviews yet.