Schneider Electric is a name that resonates with quality and innovation in the electrical and automation sectors. One of their standout products is the Schneider C11B6TM063L, a component that’s making waves in various industries. But what exactly is it, and why is it so important? Let’s dive in and explore everything you need to know about this remarkable piece of technology.
What is Schneider C11B6TM063L?
The Schneider C11B6TM063L is a versatile and robust electrical component used in a myriad of applications. It’s designed to provide superior performance, ensuring that systems run smoothly and efficiently. Known for its high reliability and durability, this component is a favorite among engineers and technicians.
Key Features and Specifications
The Schneider C11B6TM063L boasts several impressive features. It includes advanced circuitry for optimal performance, robust construction for longevity, and compatibility with a wide range of systems. Additionally, its design facilitates easy installation and maintenance, making it a go-to choice for many professionals.
Commercial Applications
Commercially, this component is used in building management systems, HVAC controls, and energy management solutions. Its efficiency and reliability make it an excellent choice for ensuring that commercial operations run smoothly.
Technical Specifications
Understanding the technical specifications of the Schneider C11B6TM063L can help you determine if it’s the right fit for your needs.
Electrical Specifications
The Schneider C11B6TM063L is designed to handle a wide range of electrical requirements. It operates efficiently under various voltages and currents, making it versatile for different applications.
Step-by-Step Installation Guide
- Prepare the Site: Clean the area and ensure it’s free from any obstructions.
- Mount the Component: Securely mount the Schneider C11B6TM063L in its designated spot.
- Connect the Wiring: Carefully connect the wiring according to the manufacturer’s guidelines.
- Test the Installation: Once installed, test the component to ensure it’s functioning correctly.
Maintenance and Troubleshooting
Regular maintenance of the Schneider C11B6TM063L will extend its lifespan and ensure it continues to operate efficiently.
Regular Maintenance Tips
- Inspect Regularly: Check the component regularly for any signs of wear or damage.
- Clean Periodically: Keep the component clean to prevent dust and debris from affecting its performance.
- Update Software: If applicable, ensure any software associated with the component is up-to-date.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63B |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 5.58 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 63 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 11.5 cm |
| Package 1 Length | 21.0 cm |
| Package 1 Weight | 1.528 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 9.546 kg |