No products in the cart.
new-36%On Sale
Schneider C11E6TM032L | Circuit breaker, ComPacT NSXm 63E, 16kA/415VAC, 4 poles 3D, TMD trip unit 32A,
C11E6TM032L
Description
Schneider C11E6TM032L | Circuit breaker, ComPacT NSXm 63E, 16kA/415VAC, 4 poles 3D, TMD trip unit 32A, EverLink lugs
Schneider C11E6TM032L Description
The Schneider C11E6TM032L is a surge protection device engineered to protect electrical installations from transient overvoltages caused by lightning strikes or electrical switching operations. Here’s a detailed description:
Schneider C11E6TM032L Surge Protector
Key Features:
- Surge Protection:
- Provides effective protection against transient overvoltages, safeguarding sensitive electronic and electrical equipment.
- Ideal for use in residential, commercial, and industrial settings.
- Voltage Rating:
- Designed to operate within specific voltage ranges, ensuring broad compatibility with various electrical systems.
- Maximum Surge Current Rating:
- Capable of handling significant surge currents, typically specified in kiloamperes (kA), providing high-level protection.
- Response Time:
- Features a fast response time to transient overvoltages, minimizing the potential for damage to connected equipment.
- Design:
- Compact and robust design suitable for integration into different environments.
- Easy to install in electrical panels or distribution boards.
- Indicator Lights:
- Equipped with LED indicators to display the operational status, allowing users to monitor the device’s functionality.
- Installation:
- Designed for straightforward installation with clear instructions and mounting options.
Applications:
- Residential: Protects household electronics, appliances, and home automation systems from power surges.
- Commercial: Safeguards office equipment, computers, and telecommunication systems.
- Industrial: Provides protection for sensitive industrial machinery and control systems.
Benefits:
- Enhanced Equipment Protection: Helps extend the lifespan of electronic devices by shielding them from harmful power surges.
- Cost Savings: Reduces the risk of equipment damage and associated repair or replacement costs.
- Increased Reliability: Ensures continuous operation of critical systems by preventing downtime caused by electrical surges.
- Peace of Mind: Provides users with confidence that their electrical systems and devices are protected against unpredictable power surges.
Considerations:
- Compatibility: Ensure the surge protector is compatible with your specific electrical system and voltage requirements.
- Maintenance: Regularly check indicator lights and replace the device if necessary to maintain optimal protection.
- Professional Installation: For complex installations, consider professional assistance to ensure proper setup and integration.
Schneider Electric is renowned for its high-quality surge protection solutions, and the C11E6TM032L is a reliable choice for safeguarding electrical systems from transient overvoltages.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63E |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 32 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | E 16 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 2.94 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 32 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13 cm |
| Package 1 Width | 12 cm |
| Package 1 Length | 22 cm |
| Package 1 Weight | 1.6 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 254.49 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider C11E6TM032L | Circuit breaker, ComPacT NSXm 63E, 16kA/415VAC, 4 poles 3D, TMD trip unit 32A,” Cancel reply
Recommended for you
Schneider C12N3TM160B | Circuit breaker ComPacT NSXm N (50kA at 415VAC), 3 Poles 3d, 160A rating TMD trip unit, compression lugs and busbar connectors
Schneider C12N3TM125B | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 3 poles, TMD trip unit 125A, lugs/busbars
Schneider C12E6TM125L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 3d, 125A rating TMD trip unit, EverLink connectors
Schneider C12B3TM160B | Circuit breaker, ComPacT NSXm 160B, 25kA/415VAC, 3 poles, TMD trip unit 160A, lugs/busbars
Schneider C12B3TM125B | Circuit breaker, ComPacT NSXm 160B, 25kA/415VAC, 3 poles, TMD trip unit 125A, lugs/busbars
Circuit Breakers and Switches, ComPacT NSXm, new generation, ComPacT NSXm, new generation, Low Voltage Products and Systems, Molded Case Circuit Breakers - MCCB
-
0
Reviews
There are no reviews yet.