No products in the cart.
new-34%On Sale
Schneider A9F77232 | Miniature circuit-breaker, Acti9 iC60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
A9F77232
Description
Schneider A9F77232 | Miniature circuit-breaker, Acti9 iC60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Schneider A9F77232 Description
The Schneider A9F77232 is a robust miniature circuit breaker (MCB) from the Acti9 series, designed to provide reliable protection and ensure the safety of electrical circuits in various applications, including residential, commercial, and industrial environments.
Schneider A9F77232: Technical Specifications and Features
Technical Specifications:
- Product Range: Acti9
- Product Type: Miniature Circuit Breaker (MCB)
- Number of Poles: 2
- Rated Current: 32 A
- Tripping Curve: D-curve
- Breaking Capacity: 10 kA at 230/400V AC
- Rated Voltage: 230/400V AC
- Frequency: 50/60 Hz
- Standards: IEC/EN 60898-1
Key Features:
- Safety Indicators: VisiTrip indicators allow for quick identification of tripped circuits, facilitating faster maintenance and reducing downtime.
- High Breaking Capacity: With a breaking capacity of 10 kA, the A9F77232 provides robust protection against short circuits and overloads.
- D-Curve Tripping: Designed for applications with high inrush current loads, the D-curve tripping characteristic offers enhanced protection for equipment such as motors and transformers.
- Dual-Pole Configuration: Featuring a dual-pole configuration, the A9F77232 is suitable for protecting circuits requiring two-pole switching.
- Ease of Installation: The Acti9 series is known for its modular design, ensuring easy installation on DIN rails, which facilitates straightforward upgrades and replacements.
- Durability: Constructed from high-quality materials, the A9F77232 ensures long-term reliability and performance even in demanding operating conditions.
- Compatibility: Compatible with a wide range of Acti9 series accessories, including auxiliary contacts and remote control units, which enhances its functionality and adaptability.
- Eco-Friendly: Schneider Electric emphasizes sustainability, ensuring the A9F77232 is manufactured using eco-friendly materials and processes.
Applications:
- Residential Buildings: Provides reliable protection for electrical circuits in homes, safeguarding against overloads and short circuits.
- Commercial Buildings: Ensures the safety and efficiency of electrical systems in offices, shops, and other commercial establishments.
- Industrial Settings: Suitable for industrial applications requiring robust circuit protection, particularly in environments with high inrush currents.
Benefits of Using Schneider A9F77232
- Enhanced Safety: Clear trip indicators and robust construction minimize the risk of electrical hazards.
- Cost-Effective Maintenance: Easy fault identification and straightforward replacement reduce maintenance costs and downtime.
- Versatility: Suitable for a wide range of applications, offering flexibility and adaptability to different electrical circuit requirements.
- Long-Term Reliability: High-quality construction ensures longevity, reducing the need for frequent replacements and enhancing overall system reliability.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 32 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| net weight | 0.25 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.200 cm |
| Package 1 Width | 3.500 cm |
| Package 1 Length | 9.400 cm |
| Package 1 Weight | 239.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 7.800 cm |
| Package 2 Width | 9.500 cm |
| Package 2 Length | 22.500 cm |
| Package 2 Weight | 1.489 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 16.976 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider A9F77232 | Miniature circuit-breaker, Acti9 iC60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)” Cancel reply
Recommended for you
-
0
Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94125 | Miniature circuit-breaker, Acti9 iC60L, 1P, 25 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F77320 | Miniature circuit-breaker, Acti9 iC60N, 3P, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9F74104 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 4A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
-
0
Reviews
There are no reviews yet.