schneider A9F87332 | Miniature circuit-breaker, Acti9 iC60H, 3P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
Miniature circuit-breaker, Acti9 iC60H, 3P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
schneider A9F87332 description
Circuit breakers are essential for protecting electrical systems from overcurrents and short circuits. This article will delve into the Schneider A9F87332, a miniature circuit breaker (MCB) known for its reliability and efficiency.
Schneider A9F87332
The Schneider A9F87332 is a 1-pole, 32A MCB from the Acti9 series. It features a C curve, making it suitable for protecting circuits with moderate inrush currents, such as lighting and distribution circuits. This MCB is designed for both residential and commercial applications, ensuring high safety and operational efficiency.
How Circuit Breakers Work
Circuit breakers safeguard electrical systems by automatically cutting off the power supply when an overcurrent or short circuit is detected. They monitor the current flow and trip to stop the flow of electricity when anomalies are found, preventing damage to the electrical circuit.
Types of Circuit Breakers
There are various types of circuit breakers, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), and more. Each type has its specific function, from protecting against overloads and short circuits to detecting residual currents.
Importance in Safety
Circuit breakers are crucial for electrical safety. They help prevent potential hazards like fires, equipment damage, and electric shocks by interrupting overcurrents and short circuits. Their role in safeguarding electrical systems is indispensable.
Installation Process
Installing a circuit breaker such as the Schneider A9F87332 involves several steps:
- Turn off the main power: Ensure the main power supply is off to avoid any accidents.
- Identify the circuit: Determine where the MCB will be installed.
- Connect the MCB: Securely connect the MCB to the circuit, making sure all connections are tight and correct.
- Test the installation: After installation, test the MCB to ensure it trips and resets correctly.
Maintenance Tips
Regular maintenance of circuit breakers is essential to ensure their proper functioning:
- Periodic testing: Regularly test the MCB to ensure it operates correctly.
- Check for damage: Inspect the MCB for any physical damage or signs of wear.
- Replace faulty units: Replace any malfunctioning MCBs promptly to maintain safety.
Common FAQs
- What is the difference between an MCB and an RCCB?
- An MCB protects against overloads and short circuits, while an RCCB detects residual currents to prevent electric shocks.
- Can MCBs be used in residential applications?
- Yes, MCBs like the Schneider A9F87332 are suitable for both residential and commercial applications.
- What does the ‘C curve’ mean in an MCB?
- The ‘C curve’ indicates the MCB’s tripping characteristics, suitable for circuits with moderate inrush currents.
- How often should an MCB be tested?
- It’s recommended to test MCBs at least once a year to ensure they function properly.
- Are MCBs affected by environmental factors?
- Yes, extreme temperatures and humidity can affect MCB performance, so it’s important to consider the installation environment.
Conclusion
The Schneider A9F87332 MCB is a reliable and efficient solution for protecting electrical circuits from overcurrents and short circuits. With proper installation and maintenance, it ensures the safety and longevity of electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 32 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60898-1 IEC 60898-1 EN 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 15 kA 100 % conforming to EN 60947-2 - 125...180 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.5 cm |
| Package 1 Width | 5.4 cm |
| Package 1 Length | 9.4 cm |
| Package 1 Weight | 196.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.2 cm |
| Package 2 Width | 9.8 cm |
| Package 2 Length | 22.2 cm |
| Package 2 Weight | 1.504 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 17.031 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18469 | Miniature circuit-breaker, Acti9 C120H, 3P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18369 | Miniature circuit-breaker, Acti9 C120N, 3P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0
Reviews
There are no reviews yet.