Schneider A9K24263 | Miniature circuit-breaker, Acti9 iK60N, 2P, 63 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24263 | Miniature circuit-breaker, Acti9 iK60N, 2P, 63 A, C curve, 6000 A (IEC60898-1)
Description
Schneider A9K24263 | Miniature circuit-breaker, Acti9 iK60N, 2P, 63 A, C curve, 6000 A (IEC60898-1)
1. Technical Specifications
-
Rated Operational Voltage (Ue): Up to 240/415 V AC
-
Number of Poles: 2 (for two-phase systems or phase + neutral)
-
Rated Current (In): 63 Amperes
-
Tripping Characteristic: Type C — designed for circuits with moderate inrush currents, suitable for most residential and commercial loads
-
Breaking Capacity: 6000 A (under IEC 60898-1)
-
Mounting System: 35 mm DIN rail (clip-on)
-
Degree of Protection: IP20 (IP40 with suitable enclosure)
-
Insulation Class: Class II (double/reinforced insulation)
-
Electrical Endurance: Up to 20,000 cycles under load
-
Mechanical Endurance: Up to 20,000 manual operations
-
Ambient Operating Temperature: -25°C to +70°C
-
Standards Compliance: IEC 60898-1
2. Key Features
-
High Current Capacity: Designed to safely manage and protect circuits rated up to 63 A
-
Double-Pole Design: Simultaneous disconnection of both conductors (phase and neutral or two phases), enhancing safety and isolation
-
C Curve Tripping Behavior: Provides reliable protection for circuits with normal to moderately inductive loads, including lighting, motors, and HVAC
-
Compact Format: Slim profile suitable for modern distribution boards
-
Safe and Quick Installation: Equipped with finger-safe terminals and DIN rail mount
-
Durability: Built to deliver long-term reliability in demanding environments
-
Visual Indicator: Clear ON/OFF status for easy monitoring
-
Accessory Compatibility: Works with selected Acti9 accessories like auxiliary contacts or shunt trips
-
Eco-Conscious Design: RoHS-compliant and manufactured with recyclable materials
3. Typical Applications
The Schneider A9K24263 MCB is widely used in various residential, commercial, and light industrial installations requiring high-load, two-pole protection:
-
Main Distribution Boards: For isolating and protecting high-load single-phase circuits
-
Residential Installations: Protection for large appliances like water heaters, ovens, or HVAC systems
-
Commercial Units: For lighting circuits, office equipment, or HVAC systems in shops and offices
-
Light Industrial Systems: Small machines or pump control panels
-
Control Panels: Used in industrial control and automation panels
-
Institutional Buildings: Schools, hospitals, and administrative facilities requiring robust protection
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iK60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iK60N |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 63 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
| Standards | EN/IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60898-1 |
| Contact position indicator | No |
| control type | Toggle |
| local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 4 |
| height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| Net weight | 200 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 |
|---|---|
| Pollution degree | 2 conforming to EN/IEC 60898-1 |
| Overvoltage category | II |
| ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.6 cm |
| Package 1 Width | 7.5 cm |
| Package 1 Length | 9.4 cm |
| Package 1 Weight | 258 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 9 cm |
| Package 2 Width | 10 cm |
| Package 2 Length | 22 cm |
| Package 2 Weight | 1.6 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 18.087 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9K24263
Main Document
Data Sheet : A9K24263
Reviews (0)
Recommended for you
Schneider A9N61502 | miniature circuit breaker – C60H – 1 pole – 2 A – C curve
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.