Schneider A9F94216 | Miniature circuit-breaker, Acti9 iC60L, 2P, 16 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
Description
Schneider A9F94216 | Miniature circuit-breaker, Acti9 iC60L, 2P, 16 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
schneider A9F94216 description
The Schneider A9F94216 is a circuit breaker designed for high-efficiency electrical protection. As part of Schneider Electric’s range, it embodies the company’s commitment to delivering top-notch safety solutions. This device is engineered to safeguard electrical circuits from overloads and short circuits, thus preventing potential damage and ensuring continuous operation.
Key Features
- Compact Design: Despite its small size, the A9F94216 provides powerful protection.
- Thermal Magnetic Mechanism: It combines thermal and magnetic trip units for reliable operation.
- High Breaking Capacity: Capable of handling substantial electrical faults without failing.
Technical Specifications
Voltage and Current Ratings
The A9F94216 is designed to operate efficiently within a specific voltage and current range. Its voltage rating ensures it can handle typical residential and commercial voltages, while the current rating provides adequate protection for various circuit sizes.
Mechanical Characteristics
The breaker’s mechanical design ensures durability and ease of use. It features a user-friendly interface for manual operation and inspection.
Environmental Conditions
The A9F94216 is built to withstand various environmental conditions, making it suitable for different installation environments, from dry indoor areas to more challenging conditions.
Benefits of Using Schneider A9F94216
Enhanced Safety
With its advanced protection mechanisms, the A9F94216 minimizes the risk of electrical fires and equipment damage. Its precise tripping characteristics ensure that circuits are protected without unnecessary interruptions.
Reliable Performance
Schneider’s A9F94216 is renowned for its reliability. The breaker’s consistent performance reduces downtime and maintenance needs, ensuring that your electrical systems remain operational.
Energy Efficiency
By preventing overloads and short circuits, the A9F94216 helps maintain energy efficiency, reducing wastage and optimizing power use.
Installation and Setup
Installation Instructions
Installing the A9F94216 is straightforward if you follow the provided guidelines. Ensure that the circuit is de-energized before installation to avoid any risk of electric shock. Mount the breaker securely and connect it to the electrical circuit as per the manufacturer’s instructions.
Common Installation Mistakes to Avoid
- Improper Wiring: Ensure correct connections to avoid malfunction.
- Inadequate Mounting: The breaker must be securely mounted to prevent movement or damage.
Applications
Residential Use
In residential settings, the A9F94216 offers protection for home electrical systems, including lighting and appliances. It ensures that your household circuits are shielded from electrical faults.
Commercial Use
For commercial establishments, this breaker provides reliable protection for more complex electrical systems, supporting a range of equipment and machinery.
Industrial Use
In industrial environments, the A9F94216 is ideal for safeguarding heavy-duty electrical installations. Its robust design and high breaking capacity make it suitable for demanding applications.
Comparison with Other Schneider Models
A9F94216 vs. A9F94215
The A9F94216 offers additional features compared to the A9F94215, such as enhanced protection settings and a higher current rating, making it more suitable for demanding applications.
A9F94216 vs. A9F94217
While both models offer similar functionalities, the A9F94217 may include additional features or different ratings tailored for specific requirements.
Maintenance Tips
Routine Checks
Regular inspections of the A9F94216 ensure that it is functioning correctly. Check for any signs of wear or damage and ensure the breaker is securely mounted.
Troubleshooting Common Issues
If the breaker trips frequently or shows signs of malfunction, inspect the circuit for potential issues such as overloads or short circuits. Consult the user manual for troubleshooting tips.
Safety Considerations
Handling and Storage
Handle the A9F94216 with care to avoid damage. Store it in a dry, cool place to maintain its performance and longevity.
Safety Protocols During Installation
Always follow electrical safety protocols during installation. Wear appropriate protective gear and ensure the power is off before working on the electrical system.
Regulatory Standards
Compliance with Electrical Codes
The A9F94216 complies with relevant electrical codes and standards, ensuring that it meets safety and performance requirements.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60L |
| poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 16 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 IEC 60898-1 EN 60947-2 EN 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 12.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 10 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 12.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 10 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 25 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 25 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 35 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 35 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 7500 A 50 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 50 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 20 kA 100 % conforming to EN 60947-2 - 72...125 V DC 20 kA 100 % conforming to IEC 60947-2 - 72...125 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| Net weight | 0.25 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.3 cm |
| Package 1 Width | 3.6 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 224.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8.0 cm |
| Package 2 Width | 10.0 cm |
| Package 2 Length | 22.5 cm |
| Package 2 Weight | 1.392 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.799 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F94216
Main Document
Data Sheet : A9F94216
Reviews (0)
Recommended for you
Schneider A9N61502 | miniature circuit breaker – C60H – 1 pole – 2 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18369 | Miniature circuit-breaker, Acti9 C120N, 3P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.