Schneider ATS01N106FT | soft starter for asynchronous motor, Altistart 01, ATS01, 6A, 110 to 480V, 0.75 to 3kW
Schneider ATS01N106FT | soft starter for asynchronous motor, Altistart 01, ATS01, 6A, 110 to 480V, 0.75 to 3kW
Description
Schneider ATS01N106FT | soft starter for asynchronous motor, Altistart 01, ATS01, 6A, 110 to 480V, 0.75 to 3kW
Technical Specifications
Electrical Specifications
-
Rated Current: 6A
-
Supported Voltage: 110V to 480V AC
-
Power Range: 0.75 kW to 3 kW (depending on the voltage)
-
Frequency: 50/60 Hz
-
Motor Type: Asynchronous motors
Design and Build Schneider ATS01N106FT
-
Compact and Lightweight: Ideal for easy panel installation
-
Mounting: DIN rail or panel mount
-
Material: High-quality, durable components for industrial use
-
Protection Rating: Designed to withstand typical industrial environments
Connections and Interfaces
-
Input and Output Terminals: Suitable for various control systems
-
Control Interface: Adjustable settings for different motor applications
-
Integrated Bypass: Reduces heat dissipation and increases efficiency
Key Features
-
Smooth Motor Startup
-
Limits high inrush current during motor startup, reducing stress on electrical systems.
-
-
Compact and Easy Installation
-
Small footprint allows for seamless integration into control panels with minimal wiring.
-
-
Energy Efficiency
-
Reduces power consumption during motor startup, improving overall energy savings.
-
-
Extended Motor Life
-
Minimizes mechanical stress, reducing wear and tear on motors and connected equipment.
-
-
Built-in Protection Features
-
Provides safeguards against motor overheating, phase failure, and power fluctuations.
-
-
Cost-Effective Solution
-
Affordable alternative to traditional motor starters, offering enhanced motor control with lower maintenance costs.
-
Applications
1. Industrial Automation
-
Used in production lines and automated systems where controlled motor startup is required.
2. HVAC Systems
-
Ideal for controlling fans, compressors, and pumps in heating, ventilation, and air conditioning systems.
3. Water and Wastewater Treatment
-
Applied in pumps and treatment equipment to ensure smooth and efficient operation.
4. Conveyor Systems
-
Helps in controlling belt conveyors, reducing mechanical shock and prolonging system life.
5. Small Machinery and Workshop Equipment
-
Suitable for small industrial machines, woodworking tools, and metalworking equipment.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of Product | Altistart 01 |
|---|---|
| Product or Component Type | Soft starter |
| product destination | Asynchronous motors |
| Product Specific Application | Simple machine |
| Device short name | ATS01 |
| Phase | 1 phase |
| [Us] rated supply voltage | 110...480 V - 10...10 % |
| Motor power kW | 3 kW, 3 phase 400 V 0.75 kW, 3 phase 230 V 1.1 kW, 3 phase 230 V 2.2 kW, 3 phase 400 V 0.75 kW, 1 phase 230 V |
| Maximum Horse Power Rating | 1 hp, 3 phase 230 V 2 hp, 3 phase 460 V 3 hp, 3 phase 460 V 0.5 hp, 3 phase 210 V 1.5 hp, 3 phase 230 V |
| IcL starter rating | 6 A |
| Utilisation category | AC-53B EN/IEC 60947-4-2 |
| Current consumption | 30 A at nominal load |
| Type of start | Start with voltage ramp |
| Power dissipation in W | 1 W at full load and at end of starting 31 W in transient state |
| Assembly style | With heat sink |
|---|---|
| Function Available | Integrated bypass |
| Supply voltage limits | 99…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Network Frequency | 47.5...63 Hz |
| Output voltage | <= power supply voltage |
| [Uc] control circuit voltage | 110 V AC +/- 10 % 30 mA 24 V AC/DC +/- 10 % 25 mA 240 V AC +/- 10 % 65 mA |
| Starting time | 1 s / 100 5 s / 20 Adjustable from 1 to 5 s |
| Starting torque | 30...80 % of starting torque of motor connected directly on the line supply |
| Discrete output current | 2 A DC-13 3 A AC-15 |
| Tightening torque | 7.08 lbf.in (0.8 N.m) |
| Electrical connection | Cage type connector - rigid 1 2.5 mm² AWG 14 control circuit Cage type connector - rigid with cable end 1 2.5 mm² AWG 14 power circuit Cage type connector - rigid without cable end 2 1 mm² AWG 17 control circuit Cage type connector - rigid without cable end 2 1 mm² AWG 17 power circuit Cage type connector - flexible with cable end 1 2.5 mm² AWG 14 control circuit Cage type connector - flexible with cable end 1 2.5 mm² AWG 14 power circuit Cage type connector - flexible without cable end 1 2.5 mm² AWG 14 control circuit Cage type connector - flexible without cable end 1 2.5 mm² AWG 14 power circuit Cage type connector - flexible with cable end 2 0.75 mm² AWG 18 control circuit Cage type connector - flexible with cable end 2 0.75 mm² AWG 18 power circuit Cage type connector - flexible without cable end 2 1 mm² AWG 17 control circuit Cage type connector - flexible without cable end 2 1 mm² AWG 17 power circuit |
| Marking | CE |
| Operating position | Vertical +/- 10 degree |
| Height | 3.9 in (100 mm) |
| Width | 0.9 in (23 mm) |
| Depth | 3.9 in (100 mm) |
| Net Weight | 0.35 lb(US) (0.16 kg) |
| Compatibility code | ATS01N1 |
| Motor power range AC-3 | 0.55…1 kW 200…240 V 3 phase 1.1…2 kW 380…440 V 3 phase 0.55…1 kW 200…240 V 1 phase 1.1…2 kW 200…240 V 3 phase 2.2…3 kW 380…440 V 3 phase |
| Motor starter type | Soft starter |
| Electromagnetic compatibility | Conducted and radiated emissions level B CISPR 11 Conducted and radiated emissions level B IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 EMC immunity level 3 EN 50082-1 EMC immunity level B EN 50082-2 Harmonics level 3 IEC 1000-3-2 Harmonics level 3 IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Micro-cuts and voltage fluctuation IEC 61000-4-11 Voltage/current impulse level 3 IEC 61000-4-5 |
|---|---|
| Standards | EN/IEC 60947-4-2 |
| Product Certifications | C-tick CCC CSA UL GOST |
| IP Degree of Protection | IP20 |
| Pollution degree | 2 EN/IEC 60947-4-2 |
| Vibration resistance | 1 gn 13…150 Hz)EN/IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6 |
| Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation or dripping water EN/IEC 60068-2-3 |
| Ambient air temperature for operation | 14.0000000000…104.0000000000 °F (-10…40 °C) without derating) 104.0000000000…122.0000000000 °F (40…50 °C) with current derating of 2 % per °C) |
| Ambient air temperature for storage | -13.0000000000…158.0000000000 °F (-25…70 °C) EN/IEC 60947-4-2 |
| Operating altitude | <= 3280.84 ft (1000 m) without derating > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m |
| Category | US10I1122392 |
|---|---|
| Discount Schedule | 0I11 |
| GTIN | 3389110667141 |
| Returnability | Yes |
| Country of origin | DE |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.0 in (2.5 cm) |
| Package 1 Width | 4.06 in (10.3 cm) |
| Package 1 Length | 4.1 in (10.5 cm) |
| Package 1 Weight | 6.3 oz (178.0 g) |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 5.9 in (15.0 cm) |
| Package 2 Width | 11.8 in (30.0 cm) |
| Package 2 Length | 15.7 in (40.0 cm) |
| Package 2 Weight | 14.804 lb(US) (6.715 kg) |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider NSYSFD2010 | Spacial SF plain door – 2000×1000 mm
Schneider NSYBP208 | Spacial SF rear panel external fixing – 2000×800 mm
-
0
Schneider NSYSM2012602D | PanelSeT SM compact enclosure without mounting plate – 2000x1200x600 mm
Schneider NSYSM2010402D | Spacial SM compact enclosure without mounting plate – 2000x1000x400 mm
-
0
Schneider LC1DPKM7 | Capacitor contactor, TeSys D, 30 kVAR at 400 V/50 Hz, coil 220 V AC 50/60 Hz
-
0
Reviews