Description

Schneider C16F32D160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, MicroLogic 2.2 trip unit 160A

Schneider C16F32D160: Product Overview and Applications

Introduction

The Schneider C16F32D160 is a high-capacity molded case circuit breaker (MCCB) designed to deliver reliable protection for large-scale electrical systems. With a rated current of 160A, this MCCB is particularly suited for applications requiring high-performance protection from overloads, short circuits, and electrical faults. The C16F32D160 is engineered with Schneider’s quality standards, making it a robust choice for use in industrial, commercial, and high-demand electrical infrastructures.

Key Features of Schneider C16F32D160

  • High Current Capacity (160A): Suitable for high-demand applications, providing solid protection in large electrical systems.
  • Thermal-Magnetic Trip Mechanism: Ensures protection with thermal sensing for overloads and magnetic sensing for instantaneous short-circuit response.
  • High Breaking Capacity: Built to handle significant fault currents, providing reliable performance under heavy electrical loads.
  • Durable and Compact Design: Engineered for longevity and reliability, and fits easily into electrical panels despite its high capacity.
  • Adjustable Trip Settings: Allows for customized protection based on the application’s specific needs, enhancing both safety and operational flexibility.

Applications of Schneider C16F32D160

  1. Industrial Machinery and Equipment: Protects high-power machinery in manufacturing plants, such as motors, conveyors, and heavy-duty equipment.
  2. Commercial Power Distribution: Suitable for commercial buildings with high electrical loads, ensuring stability in lighting, HVAC systems, and elevators.
  3. Power Distribution for Data Centers: Provides critical protection for data centers, where stable power distribution is essential for server and network reliability.
  4. Utility and Energy Applications: Ideal for substations and utility networks, supporting fault protection and stability across extensive energy grids.
  5. Renewable Energy Systems: Suitable for high-capacity renewable energy installations, such as solar farms, protecting against potential faults in power generation and distribution.

Benefits of Using Schneider C16F32D160

  • Enhanced System Safety: Robust protection reduces the risk of damage to equipment and personnel in high-power environments.
  • Reliable Performance: With a high breaking capacity and efficient fault response, this MCCB ensures uninterrupted operation even under heavy loads.
  • Adaptability Across Applications: Adjustable settings and high capacity make it versatile enough for industrial, commercial, and renewable applications.
  • Compact and Efficient Design: Designed for ease of installation and panel integration, saving valuable space in high-capacity setups.

Conclusion

The Schneider C16F32D160 is a top-tier solution for electrical protection in high-demand applications. With its thermal-magnetic trip unit, high current capacity, and robust design, it is suited for a variety of settings that require reliable power protection. From industrial machinery and data centers to renewable energy installations, this MCCB provides a dependable solution for users looking to enhance safety, performance, and reliability in their electrical systems.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX160F
Product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 160 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508
Performance level F 36 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Power dissipation per pole 9.22 W
Mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Trip unit rating 160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 63...160 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 2400 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.2 kg
Environment
Standards EN/IEC 60947-2
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000 m...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.200 cm
Package 1 Width 11.700 cm
Package 1 Length 19.500 cm
Package 1 Weight 1.874 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 13.514 kg

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider C16F32D160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, MicroLogic 2.2 trip unit 160A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare