Schneider C16F6TM160 | Circuit breaker ComPacT NSX160F, 36kA at 415VAC, TMD trip unit 160A, 4 poles 3d
Schneider C16F6TM160 | Circuit breaker ComPacT NSX160F, 36kA at 415VAC, TMD trip unit 160A, 4 poles 3d
Description
Schneider C16F6TM160 | Circuit breaker ComPacT NSX160F, 36kA at 415VAC, TMD trip unit 160A, 4 poles 3d
Schneider C16F6TM160: Product Overview and Applications
Introduction
The Schneider C16F6TM160 is a molded case circuit breaker (MCCB) built to deliver reliable circuit protection for medium- to high-power electrical systems. With a rated current of 160A, this MCCB is suited for industrial, commercial, and high-capacity applications where safeguarding against overloads, short circuits, and electrical faults is essential. The C16F6TM160 integrates thermal and magnetic trip units for precise fault response, providing high-performance protection with Schneider’s trusted engineering.
Key Features of Schneider C16F6TM160
- High Current Rating (160A): Suitable for systems with moderate to high power demands, ensuring dependable protection for essential circuits.
- Thermal-Magnetic Trip Mechanism: Features a dual-mode trip unit that offers thermal sensing for overload protection and magnetic sensing for immediate response to short circuits.
- High Breaking Capacity: Designed to handle significant fault currents, ensuring stability and safety in high-load environments.
- Robust and Compact Design: Built for longevity and resilience, this MCCB fits into standard panels while delivering reliable circuit protection.
- Adjustable Trip Settings: Allows customized protection, adapting to varying application requirements for optimized safety and operational flexibility.
Applications of Schneider C16F6TM160
- Industrial Equipment and Machinery: Protects high-power machinery, such as motors, pumps, and conveyor systems, in manufacturing and processing facilities.
- Commercial Power Distribution: Provides reliable circuit protection for commercial properties with high energy demands, including lighting, HVAC, and elevator systems.
- Data Centers and IT Infrastructure: Ensures stable power for essential systems, protecting against faults in data centers, server rooms, and communication hubs.
- Renewable Energy Installations: Ideal for use in medium- to high-capacity renewable energy systems, such as solar farms, where dependable fault protection is crucial.
- Utility and Substation Applications: Suitable for use in utility networks and substations, ensuring continuity of service and fault tolerance across complex power grids.
Benefits of Using Schneider C16F6TM160
- Enhanced Protection for High-Demand Applications: Provides robust circuit protection for high-power equipment and systems, reducing the risk of electrical damage.
- Versatility Across Multiple Settings: Suitable for both industrial and commercial uses, with adjustable settings that make it adaptable to different environments.
- Space-Efficient Design: Compact and easy to install in various panel configurations, maximizing space and efficiency.
- Low Maintenance and High Reliability: Designed to operate with minimal maintenance requirements, ensuring continuous protection with high dependability.
Conclusion
The Schneider C16F6TM160 MCCB is an excellent choice for those requiring robust protection in medium- to high-capacity electrical systems. With its 160A rating, dual-mode trip mechanism, and compact design, it offers high performance for a range of demanding applications, from industrial machinery to utility networks. Whether used in renewable energy systems or commercial infrastructure, this MCCB ensures the safety and reliability essential for any high-performance electrical setup.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX160F |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 160 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 40000 cycles |
| Electrical durability | 40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In |
| Power dissipation per pole | 13.95 W |
| Mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 160 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1250 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.6 kg |
| Standards | EN/IEC 60947-2 |
|---|---|
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 2.378 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 14.642 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18469 | Miniature circuit-breaker, Acti9 C120H, 3P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18357 | Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.