Schneider LV429564 | circuit breaker ComPact NSX100B, 25 kA at 415 VAC, TMD trip unit 40 A, 4 poles 3d
Schneider LV429564 | circuit breaker ComPact NSX100B, 25 kA at 415 VAC, TMD trip unit 40 A, 4 poles 3d
Description
Schneider LV429564 | circuit breaker ComPact NSX100B, 25 kA at 415 VAC, TMD trip unit 40 A, 4 poles 3d
1. Technical Specifications:
-
Model: LV429564
-
Type: Molded Case Circuit Breaker (MCCB)
-
Series: ComPact NSX100B
-
Operating Voltage: 415V AC
-
Breaking Capacity: 25 kA at 415V AC
-
Number of Poles: 4 Poles (4P)
-
Trip Unit: TMD (Thermal-Magnetic)
-
Rated Current: 40A
-
Protection Type: Thermal protection for overloads and magnetic protection for short circuits
2. Key Features:
-
Enhanced Safety: Provides both thermal and magnetic protection, ensuring reliable operation in electrical systems.
-
Moderate Breaking Capacity: 25 kA breaking capacity is suitable for low to medium fault current conditions.
-
4-Pole Configuration: Offers better phase and neutral protection, ideal for balanced and unbalanced loads.
-
Compact and Durable Design: Built for high efficiency in confined spaces while maintaining robust performance.
-
Versatile Applications: Suitable for various electrical systems, including industrial, commercial, and residential setups.
3. Applications:
-
Industrial Facilities: Protects electrical panels and ensures safe operation in factories and processing plants.
-
Commercial and Residential Buildings: Provides effective protection for distribution boards and main electrical systems.
-
Power Distribution Systems: Helps in securing power networks in substations and other distribution points.
-
Equipment and Machinery Protection: Safeguards motors, transformers, and other electrical devices from overloads and short circuits.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPact |
|---|---|
| Product name | ComPact NSX |
| Range of product | ComPact NSX100...250 |
| Device short name | NSX100B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Number of poles | 4P |
| Protected poles description | 3t |
| Neutral position | Left |
| [In] rated current | 40 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 10000 cycles at 690 V In 20000 cycles at 690 V In/2 30000 cycles at 440 V In 50000 cycles at 440 V In/2 |
| Mounting support | Backplate |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 40 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 500 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Neutral protection settings | No protection (3t) |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.5 cm |
| Package 1 Width | 17.7 cm |
| Package 1 Length | 17.81 cm |
| Package 1 Weight | 2.356 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 14.54 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
Schneider A9N61515 | miniature circuit breaker – C60H – 1 pole – 32 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.