Schneider TM3DQ8R | Modicon TM3 – 8 relay outputs (screw) 24Vdc
Schneider TM3DQ8R | Modicon TM3 – 8 relay outputs (screw) 24Vdc
Description
Schneider TM3DQ8R | Modicon TM3 – 8 relay outputs (screw) 24Vdc
Technical Specifications
-
Model: TM3DQ8R
-
Device Type: Discrete output expansion module
-
Number of Outputs: 8 relay outputs
-
Output Voltage Range:
-
5-30V DC
-
24-250V AC
-
-
Output Current:
-
2A per channel (max)
-
8A total (max)
-
-
Response Time:
-
On → Off: 10ms
-
Off → On: 10ms
-
-
Connection Type: Screw terminals
-
Mounting: DIN rail mounting
-
Protection Rating: IP20 (for indoor industrial environments)
-
Operating Temperature Range: -10°C to 55°C
Key Features
-
Reliable Switching for AC & DC Loads
-
Relay-based outputs allow control of both AC and DC loads, offering flexibility for different applications.
-
Suitable for controlling lights, solenoids, motors, and heating elements.
-
-
Seamless Integration with Modicon PLCs
-
Compatible with Modicon M221, M241, and M251 PLCs via the TM3 expansion bus.
-
Plug-and-play installation with no additional configuration required.
-
-
Durable & Industrial-Grade Design
-
IP20-rated enclosure ensures safe operation in industrial environments.
-
Wide operating temperature range (-10°C to 55°C) for robust performance.
-
-
Secure Wiring with Screw Terminals
-
Screw-type connectors provide a stable and secure electrical connection.
-
Reduces risk of loose wiring in industrial environments.
-
Applications & Use Cases
The Schneider TM3DQ8R relay output module is ideal for various industrial automation applications, including:
-
Machine Control
-
Switching motors, pumps, and conveyors in industrial automation.
-
-
Lighting & Building Automation
-
Controlling lighting circuits and HVAC systems in smart buildings.
-
-
Process Control & Manufacturing
-
Automating industrial machines and equipment with reliable on/off control.
-
-
Water & Wastewater Management
-
Managing valves, pumps, and alarms in water treatment systems.
-
-
Smart Agriculture & Irrigation
-
Controlling irrigation pumps and environmental monitoring systems.
-
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Modicon TM3 |
|---|---|
| Product or component type | Discrete output module |
| Range compatibility | Modicon M241 Modicon M251 Modicon M221 Modicon M262 |
| Discrete output type | Relay normally open |
| Discrete output number | 8 |
| Discrete output logic | Positive or negative |
| Discrete output voltage | 24 V DC for relay output 240 V AC |
| Discrete output current | 2000 mA for relay output |
| Discrete I/O number | 8 |
|---|---|
| Current consumption | 5 mA at 5 V DC via bus connector (at state off) 0 mA at 24 V DC via bus connector (at state off) 40 mA at 24 V DC via bus connector (at state on) 30 mA at 5 V DC via bus connector (at state on) |
| Response time | 10 ms (turn-on) 5 ms (turn-off) |
| Mechanical durability | 20000000 cycles |
| Minimum load | 10 mA at 5 V DC for relay output |
| Local signalling | 1 LED per channel (green) for output status |
| Electrical connection | 11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for outputs |
| Maximum cable distance between devices | Unshielded cable: <30 m for relay output |
| Insulation | Between output and internal logic at 2300 V AC Between outputs at 750 V AC Between output groups at 1500 V AC |
| Marking | CE |
| Mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
| Height | 90 mm |
| Depth | 84.6 mm |
| Width | 27.4 mm |
| Net weight | 0.11 kg |
| Standards | IEC 61131-2 |
|---|---|
| Product certifications | CE cULus UKCA RCM EAC cULus HazLoc |
| Resistance to electrostatic discharge | 8 kV in air conforming to IEC 61000-4-2 4 kV on contact conforming to IEC 61000-4-2 |
| Resistance to electromagnetic fields | 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3 |
| Resistance to magnetic fields | 30 A/m 50/60 Hz conforming to IEC 61000-4-8 |
| Resistance to fast transients | 2 kV for relay output conforming to IEC 61000-4-4 |
| Surge withstand | 1 kV I/O common mode conforming to IEC 61000-4-5 DC |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz conforming to IEC 61000-4-6 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
| Electromagnetic emission | Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to IEC 55011 |
| Ambient air temperature for operation | -10…35 °C vertical installation -10…55 °C horizontal installation |
| Ambient air temperature for storage | -25…70 °C |
| Relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
| IP degree of protection | IP20 with protective cover in place |
| Pollution degree | 2 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Vibration resistance | 3.5 mm at 5…8.4 Hz on DIN rail 3 gn at 8.4…150 Hz on DIN rail 3.5 mm at 5…8.4 Hz on panel 3 gn at 8.4…150 Hz on panel |
| Shock resistance | 15 gn for 11 ms |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.519 cm |
| Package 1 Width | 10.487 cm |
| Package 1 Length | 12.849 cm |
| Package 1 Weight | 240.0 g |
| Unit Type of Package 2 | CAR |
| Number of Units in Package 2 | 42 |
| Package 2 Height | 29.4 cm |
| Package 2 Width | 39.7 cm |
| Package 2 Length | 56.0 cm |
| Package 2 Weight | 10.95 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 504 |
| Package 3 Height | 105 cm |
| Package 3 Width | 120 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 130 kg |
Reviews