Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal
Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal
Description
Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal
Technical Specifications:
-
Contactor Type: The LC1D258Q7 is a 4-pole contactor designed to switch both AC loads and DC loads. It features a combination of 2 NO (normally open) contacts and 2 NC (normally closed) contacts, allowing for versatile control of electrical circuits.
-
Rated Current: The contactor has a current rating of 40A, making it suitable for switching higher-power loads. It can handle substantial electrical demands in both residential and industrial environments.
-
Coil Voltage: The LC1D258Q7 features a 380V AC 50/60Hz coil, meaning it is designed to operate in 380V AC electrical systems, commonly used in industrial settings. It ensures reliable switching in applications where this coil voltage is standard.
-
Rated Voltage: This contactor is rated for an operational voltage of ≤440V, making it compatible with a wide range of industrial applications where equipment needs to be controlled by high-voltage circuits.
-
Applications: The LC1D258Q7 contactor is primarily rated for AC-1 operations, meaning it is ideal for non-inductive or slightly inductive loads. It is commonly used for switching motors, lighting, and heating systems. It can also be used in controlling various industrial equipment and automation systems.
-
Terminal Type: This contactor uses screw clamp terminals, which provide a secure and stable connection for electrical conductors. Screw terminals ensure ease of installation and maintenance while providing excellent electrical conductivity.
-
Size and Mounting: The contactor is designed for easy DIN rail mounting, ensuring simple integration into industrial control panels. Its compact design makes it suitable for both space-constrained environments and larger, more expansive installations.
-
Environmental Ratings: This contactor is built for rugged industrial environments and offers reliable performance under varying conditions. It is designed to operate efficiently and safely in harsh environments, typical of industrial applications.
Features:
-
High Current Rating: With a 40A current rating, the LC1D258Q7 is well-suited for applications that require controlling high-power devices, such as motors, heating systems, or industrial machinery.
-
4-Pole Design: The 4-pole design with 2 NO and 2 NC contacts offers flexible control for a wide range of load switching and protection scenarios, improving operational flexibility in complex electrical circuits.
-
AC-1 Operation: Rated for AC-1 operation, it is ideal for controlling non-inductive or low-inductive loads, such as resistive heating or lighting, which helps to extend the operational life of the contactor and improve efficiency.
-
380V Coil: The 380V AC 50/60Hz coil provides compatibility with standard industrial AC voltages, ensuring optimal performance in common electrical systems used worldwide.
-
Screw Clamp Terminals: The screw clamp terminals ensure a secure and stable electrical connection, making installation easier and more reliable. It minimizes the risk of poor connections that can lead to malfunction or failure.
-
Compact and Durable: The TeSys Deca series is known for its compact size and rugged durability, which ensures that the LC1D258Q7 contactor can withstand the wear and tear of demanding industrial environments.
-
Easy Installation: The DIN rail mounting option allows for easy and fast installation in control panels, saving time and reducing the complexity of setup.
Applications:
-
Motor Control: Ideal for motor control applications, this contactor can be used to switch motors on and off in industrial machinery and equipment.
-
Heating Systems: Can be used in heating systems where a reliable on/off switch is required to control high-power heating elements.
-
Lighting Control: Perfect for controlling lighting circuits in industrial, commercial, or residential settings.
-
Automation Systems: The LC1D258Q7 can be integrated into automation systems to manage the switching of multiple devices and load types.
-
Industrial Equipment: Commonly used in industrial control panels to manage electrical circuits and processes that require high current switching.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | TeSys Deca |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1D |
| contactor application | Resistive load |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 |
| poles description | 4P |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC |
| [Ie] rated operational current | 40 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 380 V AC 50/60 Hz |
| Compatibility code | LC1D |
|---|---|
| Pole contact composition | 2 NO + 2 NC |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit 40 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 240 A 104 °F (40 °C) - 10 s for power circuit 380 A 104 °F (40 °C) - 1 s for power circuit 50 A 104 °F (40 °C) - 10 min for power circuit 120 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
| Power dissipation per pole | 3.2 W AC-1 |
| [Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.4 Mcycles 40 A AC-1 <= 440 V |
| Control circuit type | AC 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) 70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
| Connections - terminals | Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 Power circuit 15.9 lbf.in (1.8 N.m) screw clamps terminals flat Ø 6 mm Power circuit 15.9 lbf.in (1.8 N.m) screw clamps terminals Philips No 2 Power circuit 15.9 lbf.in (1.8 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate Rail |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|---|---|
| Product certifications | GL BV DNV LROS (Lloyds register of shipping) RINA UL CCC CSA GOST UKCA CB |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 8 Gn for 11 ms) |
| Height | 3.6 in (91 mm) |
| Width | 1.8 in (45 mm) |
| Depth | 3.9 in (99 mm) |
| Net weight | 0.937 lb(US) (0.425 kg) |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.57 in (9.08 cm) |
| Package 1 Width | 1.8 in (4.5 cm) |
| Package 1 Length | 3.92 in (9.95 cm) |
| Package 1 Weight | 15.3 oz (435.0 g) |
| Warranty | 18 months |
|---|
Reviews