Schneider LV525332 | circuit breaker EasyPact CVS250F, 36 kA at 415 VAC, 200 A rating thermal magnetic TM-D trip unit, 3P 3d
Schneider LV525332 | circuit breaker EasyPact CVS250F, 36 kA at 415 VAC, 200 A rating thermal magnetic TM-D trip unit, 3P 3d
Description
Schneider LV525332 | circuit breaker EasyPact CVS250F, 36 kA at 415 VAC, 200 A rating thermal magnetic TM-D trip unit, 3P 3d
Specifications:
-
Type: Circuit Breaker
-
Model: EasyPact CVS250F
-
Rated Current: 250 Amps
-
Rated Voltage: 415 VAC
-
Short-Circuit Breaking Capacity: 36 kA (at 415 VAC)
-
Trip Unit: Thermal Magnetic TM-D
-
Thermal Protection: Protects against overloads.
-
Magnetic Protection: Provides protection against short circuits.
-
-
Poles: 3P (Three Poles)
-
Design: 3d (three-phase, with adjustable settings for protection)
-
Application: Suitable for use in industrial, commercial, and residential power distribution systems.
Features:
-
High Breaking Capacity:
-
The EasyPact CVS250F has a short-circuit breaking capacity of 36 kA at 415 VAC, providing excellent protection against high fault currents, ensuring the safety of electrical systems.
-
-
Thermal Magnetic Trip Unit:
-
The TM-D trip unit combines both thermal and magnetic protection. The thermal function offers overload protection, while the magnetic function provides protection against short circuits.
-
-
Reliable Performance:
-
The breaker is designed to handle demanding electrical loads with high durability, ensuring the continuous protection of circuits.
-
-
Adjustable Protection Settings:
-
The TM-D trip unit offers adjustable protection settings, allowing the circuit breaker to be fine-tuned to meet the specific needs of the application. This feature is useful for different operating conditions and requirements.
-
-
Compact and Easy to Install:
-
The design is compact, making it easy to install and fit into existing electrical systems while providing effective protection.
-
-
Three-Pole Design:
-
As a 3-pole circuit breaker, the CVS250F is ideal for three-phase power systems, providing protection for all three phases simultaneously.
-
-
Reliable in Harsh Environments:
-
Built for industrial environments, the breaker is highly durable and offers consistent performance in challenging conditions.
-
Applications:
-
Industrial Power Systems: Suitable for use in factories, manufacturing plants, and other industrial environments requiring robust protection for electrical systems.
-
Commercial Buildings: Provides reliable protection for the electrical distribution systems in commercial buildings, ensuring the safety of both equipment and personnel.
-
Residential Power Distribution: Can be used in residential electrical panels where high current and short-circuit protection are essential.
-
Motor Protection: The breaker can be used in systems where motors and other heavy machinery are in operation, providing protection from both overloads and short circuits
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| Product name | EasyPact CVS |
| Device short name | CVS250F |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 200 A at 40 °C |
| Network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 200 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| Network frequency | 50/60 Hz |
| Breaking capacity code | F |
| [Ics] rated service breaking capacity | 18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 140…200 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| instantaneous pick-up adjustment range | 2000 A |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS250 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net weight | 1.7 kg |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Product certifications | GOST IEC |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.000 cm |
| Package 1 Width | 14.000 cm |
| Package 1 Length | 19.000 cm |
| Package 1 Weight | 1.929 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.994 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.