Schneider LV516632 | Easypact CVS – CVS160B circuit breaker – 4P/4d
Schneider LV516632 | Easypact CVS – CVS160B circuit breaker – 4P/4d
Description
Schneider LV516632 | Easypact CVS – CVS160B circuit breaker – 4P/4d
Specifications Schneider LV516632
-
Type: Circuit Breaker
-
Model: Easypact CVS160B
-
Rated Current: 160 Amps
-
Poles: 4P (Four Poles)
-
Design: 4d (Four-phase, with adjustable protection across all phases)
-
Rated Voltage: Suitable for low-voltage electrical systems
-
Protection: Provides overload, short-circuit, and earth fault protection
Features Schneider LV516632
-
Four-Pole Design:
-
The 4P (four-pole) configuration is used in systems that require protection for four conductors, including three-phase with neutral systems. This ensures comprehensive protection for all phases and the neutral conductor.
-
-
Thermal Magnetic Protection:
-
The Easypact CVS160B incorporates both thermal protection (for overloads) and magnetic protection (for short circuits). This combination ensures effective protection against both prolonged overloads and short-circuit conditions.
-
-
Adjustable Protection Settings:
-
The breaker features adjustable trip settings, which allow for tailoring the protection characteristics based on the specific requirements of the installation, ensuring optimal system safety and performance.
-
-
Compact Design:
-
The Easypact CVS160B is compact and easy to install, making it ideal for use in environments where space is limited while still offering high protection levels.
-
-
Durability:
-
Constructed for industrial use, the circuit breaker is highly durable and able to withstand the rigors of harsh environments, ensuring long-term reliable protection of electrical systems.
-
-
Easy Installation and Maintenance:
-
Its straightforward design simplifies installation and maintenance, reducing downtime and allowing for easy upgrades or servicing.
-
-
Reliable Performance:
-
This circuit breaker is engineered to provide consistent and dependable protection, ensuring the safety of electrical circuits and equipment in demanding environments.
-
Applications Schneider LV516632
-
Industrial Power Systems: Ideal for protecting equipment such as motors, distribution boards, and industrial machinery in factories, plants, and production facilities.
-
Commercial Installations: Can be used in commercial buildings, offices, and retail spaces to protect the electrical systems from overloads and short circuits.
-
Residential Power Distribution: Suitable for large residential buildings or multi-unit complexes, offering protection against electrical faults in power distribution systems.
-
Motor and Equipment Protection: Commonly used to safeguard motors and other sensitive electrical equipment, ensuring continuous operation without risk of damage due to overloads or short circuits.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| Product name | EasyPact CVS |
| Device short name | CVS160B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 4D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 125 A at 50 °C |
| Network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 125 A at 40 °C |
| Protection type | Overload protection (thermal) Short-circuit protection (magnetic) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| Network frequency | 50/60 Hz |
| Breaking capacity code | B |
| [Ics] rated service breaking capacity | 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Neutral position | Left |
| Mechanical durability | 25000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Neutral protection setting | 1 x Ir (4D) |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Short-time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| instantaneous pick-up adjustment range | 1250 A |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Compatibility code | CVS160 |
| Width | 140 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net weight | 1.9 kg |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Product certifications | GOST IEC |
| Electrical shock protection class | Class II |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Weight | 2.209 kg |
Main Document
Main Document
Data Sheet : LV516632
Main Document
Data Sheet : LV516632
Reviews (0)
Recommended for you
Schneider A9N61508 | miniature circuit breaker – C60H – 1 pole – 10 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.