Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d
Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d
Description
Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d
1. Technical Specifications
-
Model: LV510303
-
Product Series: EasyPact CVS100B
-
Breaker Type: Molded Case Circuit Breaker (MCCB)
-
Rated Current (In): 40 A
-
Breaking Capacity (Icu): 25 kA at 415V AC
-
Voltage Rating: 415V AC (50/60 Hz)
-
Trip Unit Type: TM-D (Thermal Magnetic)
-
Thermal Protection: Adjustable (typically 0.7 – 1 × In)
-
Magnetic Protection: Fixed (factory set for short-circuit protection)
-
Number of Poles: 3P
-
Pole Protection Configuration: 3d (protection on all three poles)
-
Mounting: Fixed – panel mounting
-
Standards Compliance: IEC 60947-2
-
Mechanical Durability: Up to 10,000 operations
-
Electrical Durability: Up to 4,000 operations (under standard load)
2. Key Features
High Breaking Capacity
With a fault-breaking capacity of 25 kA at 415V, the LV510303 offers solid protection even in demanding distribution systems with higher fault levels.
Reliable TM-D Trip Unit
Equipped with a thermal-magnetic (TM-D) trip unit that provides reliable protection against both overloads (long-duration overcurrent) and short circuits (instantaneous trips).
Adjustable Thermal Trip
The thermal trip setting can be fine-tuned between 70% and 100% of the rated current, enabling tailored protection based on the actual load conditions.
Full 3-Pole Protection
The 3d configuration means all three phases are protected, ensuring full system coverage in three-phase installations.
Compact and Efficient Design
The breaker offers a space-saving profile with easy integration into electrical panels, suitable for new installations or retrofit projects.
3. Typical Applications
-
Sub-Distribution Panels: Ideal for use as a feeder breaker in distribution boards.
-
Motor Control Centers: Protects motor circuits in industrial environments.
-
Lighting & Power Panels: Ensures safe distribution in commercial buildings.
-
Pumping and Irrigation Systems: Used to protect circuits feeding pumps in agricultural settings.
-
Industrial Equipment: Suitable for general-purpose protection of machinery and control panels.
-
Backup Generator Panels: Ensures safe isolation and protection of generator outputs
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| Product name | EasyPact CVS |
| Device short name | CVS100B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 40 A at 40 °C |
| network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 40 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| network frequency | 50/60 Hz |
| Breaking capacity code | B |
| [Ics] rated service breaking capacity | 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 28…40 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| instantaneous pick-up adjustment range | 500 A |
| Contact position indicator | Yes |
| mounting support | Backplate |
| mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS100 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net weight | 1.5 kg |
| Standards | IEC 60947-2 EN 60947-2 |
|---|---|
| Product certifications | IEC GOST |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.800 cm |
| Package 1 Width | 13.600 cm |
| Package 1 Length | 19.200 cm |
| Package 1 Weight | 1.654 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 40.000 cm |
| Package 2 Length | 60.000 cm |
| Package 2 Weight | 20.614 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61508 | miniature circuit breaker – C60H – 1 pole – 10 A – C curve
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18470 | Miniature circuit-breaker, Acti9 C120H, 3P, 125 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.