Schneider A9R44440 | Acti 9 iID – RCCB – 4P – 40A – 300mA – type AC
Schneider A9R44440 | Acti 9 iID – RCCB – 4P – 40A – 300mA – type AC
Description
Schneider A9R44440 | Acti 9 iID – RCCB – 4P – 40A – 300mA – type AC
Technical Specifications:
-
Rated Current (In): 40 Amps.
-
Number of Poles: 4 Poles.
-
Earth-Leakage Sensitivity (IΔn): 300 mA
-
Protection Class: Type AC (responds to alternating current leakage).
-
Rated Operational Voltage (Ue): 380–415 V AC at 50/60 Hz.
-
Rated Insulation Voltage (Ui): 500 V AC.
-
Impulse Withstand Voltage (Uimp): 6 kV.
-
Rated Conditional Short-Circuit Current (Inc/IΔc): 10 kA.
-
Rated Breaking and Making Capacity (Idm/Im): 1500 A.
-
Mounting: DIN rail mountable.
-
Width: 72 mm (8 DIN modules).
-
Height: 91 mm.
-
Depth: 73.5 mm.
-
Weight: 0.37 kg.
-
Environmental Protection: IP20 (without cover) and IP40 (with cover).
-
Operating Temperature Range: -5°C to 60°C.
-
Storage Temperature Range: -40°C to 85°C.
Features:
-
Enhanced Protection: With a sensitivity of 300 mA, the A9R44440 offers protection against higher leakage currents, making it suitable for specific applications where higher leakage thresholds are acceptable.
-
High Breaking Capacity: Capable of withstanding short-circuit currents up to 10 kA, ensuring robust protection in fault conditions.
-
Durability: Designed for longevity with electrical endurance up to 15,000 cycles and mechanical endurance up to 20,000 cycles.
-
Visitrip Indicator: Features a mechanical indicator on the front face to quickly identify the status of the device, facilitating efficient maintenance.
-
VisiSafe Window: Equipped with a window on the toggle that displays a green strip when the contacts are fully open, ensuring safe maintenance procedures.
-
Easy Installation: Designed for straightforward installation on standard DIN rails, simplifying integration into electrical panels.
-
Environmental Considerations: Constructed with a carbon footprint of 65 kg CO₂ equivalent per product lifecycle, reflecting Schneider Electric’s commitment to sustainability
Applications:
-
Residential: Protects household electrical systems from leakage currents, ensuring the safety of residents.
-
Commercial and Industrial: Safeguards electrical installations in commercial and industrial settings where higher leakage currents may occur.
-
Specific Equipment Protection: Ideal for applications requiring higher leakage sensitivity, such as certain industrial machinery or equipment with known leakage characteristics.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product name | Acti9 iID |
| Product or component type | Residual current circuit breaker (RCCB) |
| Device short name | iID |
| poles description | 4P |
| Neutral position | Left |
| [In] rated current | 40 A |
| network type | AC |
| Earth-leakage sensitivity | 300 mA |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type AC |
| Device location in system | Outgoer |
|---|---|
| network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 380...415 V AC 50/60 Hz |
| Residual current tripping technology | Voltage independent |
| Rated breaking and making capacity | Idm 1500 A Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Surge current | 250 A |
| Contact position indicator | Yes |
| Control type | Toggle |
| mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 8 |
| Height | 91 mm |
| Width | 72 mm |
| Depth | 73.5 mm |
| Net weight | 0.37 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | AC-1: 15000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Standards | EN/IEC 61008-1 EN/IEC 61008-2-1 |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.5 cm |
| Package 1 Width | 8 cm |
| Package 1 Length | 10 cm |
| Package 1 Weight | 362 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 27 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.178 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 216 |
| Package 3 Height | 45 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 93.424 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9F94463 | Miniature circuit-breaker, Acti9 iC60L, 4P, 63 A, C curve, 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.