Circuit Breakers and Switches, EasyPact circuit breakers and switches, EasyPact CVS, Low Voltage Products and Systems
Schneider LV510300 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 16 A rating thermal magnetic TM-D trip unit, 3P 3d
Schneider LV510300 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 16 A rating thermal magnetic TM-D trip unit, 3P 3d
LV510300
Description
Schneider LV510300 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 16 A rating thermal magnetic TM-D trip unit, 3P 3d
Technical Specifications
- Model: Schneider LV510300 | EasyPact CVS100B
- Rated Current: 16A
- Breaking Capacity: 25 kA at 415V AC
- Poles: 3P (Three-Pole)
- Trip Unit Type: Thermal-Magnetic TM-D
- Voltage Rating: 415V AC
- Mounting Type: Fixed
- Protection Type: Overload & Short Circuit
- Standard Compliance: IEC 60947-2
- Operating Temperature: -25°C to 70°C
Key Features
- Reliable Protection Mechanism
- Thermal-Magnetic TM-D Trip Unit ensures fast and precise disconnection in case of overloads or short circuits.
- 25 kA breaking capacity at 415V AC offers robust protection for demanding electrical environments.
- High Durability & Performance
- Designed to withstand harsh industrial and commercial conditions.
- Ensures long-term reliability and reduced maintenance needs.
- Versatile & Easy Installation
- Three-pole (3P) configuration for balanced three-phase power distribution.
- Compact design allows seamless integration into electrical panels.
- Compliance with International Standards
- Certified under IEC 60947-2, ensuring adherence to global safety and performance regulations.
Applications
The Schneider LV510300 | EasyPact CVS100B circuit breaker is widely used in various sectors, including:
Industrial Facilities – Protecting heavy machinery and electrical panels.
Commercial Buildings – Ensuring safe power distribution in offices and retail spaces.
Residential Installations – Providing enhanced protection for electrical circuits.
Power Distribution Systems – Acting as a key component in electrical switchgear.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| product name | EasyPact CVS |
| Device short name | CVS100B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 16 A at 40 °C |
| network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 16 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| Network frequency | 50/60 Hz |
| Breaking capacity code | B |
| [Ics] rated service breaking capacity | 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| control type | Toggle |
| Thermal protection adjustment range | 11.2…16 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| Instantaneous pick-up adjustment range | 190 A |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| Downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS100 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Product weight | 1.5 kg |
| Standards | IEC 60947-2 EN 60947-2 |
|---|---|
| Product certifications | IEC GOST |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.000 cm |
| Package 1 Width | 14.000 cm |
| Package 1 Length | 19.000 cm |
| Package 1 Weight | 1.710 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 14.100 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 64 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 124.800 kg |
Reviews (0)
Be the first to review “Schneider LV510300 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 16 A rating thermal magnetic TM-D trip unit, 3P 3d” Cancel reply
Recommended for you
Schneider A9N61508 | miniature circuit breaker – C60H – 1 pole – 10 A – C curve
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18369 | Miniature circuit-breaker, Acti9 C120N, 3P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Acti 9 Surge Protection Devices - SPDs, Acti9 iPRD, Electrical Protection and Control, Low Voltage Products and Systems
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
Acti 9 iK60, Acti 9 iK60, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, iC60, Low Voltage Products and Systems
-
0
Reviews
There are no reviews yet.