Schneider LC1E2510M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,25A,220V AC coil,50Hz,1NO auxiliary contact
Description
Schneider LC1E2510M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,25A,220V AC coil,50Hz,1NO auxiliary contact
Schneider LC1E2510M5: Your Comprehensive Guide
Introduction to Schneider LC1E2510M5
Schneider LC1E2510M5 is a robust and reliable contactor designed for various industrial applications. It belongs to Schneider Electric’s LC1E series, renowned for its performance and durability in controlling electrical circuits..
Applications
Schneider LC1E2510M5 finds wide-ranging applications across industries, including:
- Manufacturing plants
- Commercial buildings
- HVAC systems
- Water treatment facilities
- Mining operations
Advantages of Schneider LC1E2510M5
- Robust construction ensures durability and longevity.
- Precise engineering guarantees reliable performance under varying conditions.
- Easy installation and compatibility with standard electrical systems streamline integration processes.
- Enhanced safety features protect against electrical faults and overloads.
- Compact design saves space and allows for flexible installation options.
Installation Guide
Installing it contactor is straightforward and can be accomplished using standard electrical wiring practices. Here’s a brief guide:
- Ensure that the power supply to the circuit is switched off.
- Select an appropriate location for mounting the contactor, considering accessibility and ventilation requirements.
- Connect the control wires to the designated terminals on the contactor, following the manufacturer’s instructions.
- Securely fasten the contactor to the mounting surface using suitable hardware.
- Double-check all connections to ensure proper wiring and alignment.
- Restore power to the circuit and test the contactor’s operation.
Maintenance Tips
To ensure optimal performance and longevity of it contactor, follow these maintenance tips:
- Regularly inspect for signs of wear or damage, such as overheating or corrosion.
- Keep the contactor and its surroundings clean and free from debris.
- Test the contactor periodically to verify its functionality.
- Replace any worn-out components or damaged parts promptly.
- Follow the manufacturer’s recommendations for maintenance intervals and procedures.
Troubleshooting
In the event of operational issues or malfunctions, refer to the troubleshooting guide provided by Schneider Electric. Common troubleshooting steps may include:
- Checking for loose connections or faulty wiring
- Inspecting the contactor for signs of damage or wear
- Testing the coil voltage and continuity of the contactor
- Consulting technical support or contacting a certified electrician for assistance
Comparisons with Similar Products
When comparing it with similar products in the market, consider factors such as:
- Price
- Performance specifications
- Brand reputation
- Warranty coverage
- Additional features or functionalities
Conclusion
it stands out as a dependable solution for controlling electrical circuits in diverse industrial applications. With its robust construction, reliable performance, and ease of installation, it offers significant advantages to users seeking efficient and safe electrical control solutions.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| range of product | Easy TeSys Control |
| product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 25 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 32 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50 Hz |
| Motor power kW | 5.5 kW at 220...230 V AC 50/60 Hz 11 kW at 380...400 V 11 kW at 415 V 11 kW at 440 V 15 kW at 500 V 15 kW at 660...690 V |
|---|---|
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 32 A (at 55 °C) for power circuit |
| Irms rated making capacity | 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 200 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 240 A 40 °C - 10 s for power circuit 120 A 40 °C - 60 s for power circuit 50 A 40 °C - 600 s for power circuit |
| Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit |
| Average impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole | 1.6 W AC-3 3.2 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 1200000 cycles AC-3 350000 cycles AC-1 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz |
| Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W for control circuit |
| Operating time | 12...22 ms on closing 4...19 ms on opening |
| Maximum operating rate | 1800 cyc/h 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 1.5 N.m |
| Auxiliary contact composition | 1 NO |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| mounting support | Plate DIN rail |
| Standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 |
|---|---|
| Product certifications | EAC CE |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
| Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 85 mm |
| net weight | 0.36 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.600 cm |
| Package 1 Length | 8.200 cm |
| Package 1 Weight | 357.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 13.347 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 576 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 222.052 kg |
| Warranty | 18 months |
|---|
Main documents
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1E2510M5 |
|
Instruction sheet
|
LC1E2510M5 |
| Catalog | LC1E2510M5 |
|
Environmental disclosure
|
LC1E2510M5 |
| CAD Files | LC1E2510M5 |
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1E2510M5 |
|
Instruction sheet |
LC1E2510M5 |
| Catalog | LC1E2510M5 |
|
Environmental disclosure |
LC1E2510M5 |
| CAD Files | LC1E2510M5 |
Reviews
There are no reviews yet.