Schneider LC1E0910M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,9A,220V AC coil,50Hz,1NO auxiliary contact
Description
Schneider LC1E0910M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,9A,220V AC coil,50Hz,1NO auxiliary contact
Schneider LC1E0910M5 | Easy TeSys Control Contactor, 3P (3NO), 9A, 220V AC Coil, 1NO Auxiliary Contact
1. Introduction
The Schneider LC1E0910M5 is a 3-pole (3NO) contactor from the Easy TeSys Control series, designed for motor control and power switching in industrial and commercial applications. With a rated operational current of 9A (AC-3) at ≤440V, this contactor features a 220V AC coil (50Hz) and includes one normally open (1NO) auxiliary contact, making it suitable for various electrical control systems.
2. Key Features
- Rated Current: 9A (AC-3)
- Voltage Compatibility: ≤440V
- Number of Poles: 3P (3 Normally Open – 3NO)
- Coil Voltage: 220V AC, 50Hz
- Built-in Auxiliary Contact: 1NO (Normally Open)
- Compact & Durable Design: Ideal for industrial environments
- High Electrical Durability: Designed for long operational life
- Easy Installation: Compatible with Easy TeSys accessories and mounting systems
3. Technical Specifications
- Product Type: Power Contactor
- Series: Easy TeSys Control (LC1E)
- Rated Operational Current (Ie): 9A (AC-3)
- Rated Operational Voltage (Ue): Up to 440V AC
- Coil Voltage: 220V AC, 50Hz
- Number of Contacts: 3NO (Main), 1NO (Auxiliary)
- Mounting Type: Panel mounting
- Compliance: IEC 60947-4-1
4. Applications
- Motor control and protection (small motors, pumps, fans)
- Industrial automation systems
- HVAC and lighting control
- Power distribution panels
- General-purpose electrical switching
5. Benefits
- Reliable Performance: Ensures stable and efficient operation
- Space-Saving Design: Compact size for easy integration into control panels
- Built-in Auxiliary Contact: Provides additional control functionality
- Energy-Efficient: Optimized for low power consumption
- Easy Installation & Maintenance: Modular design for quick setup and servicing
6. Conclusion
The Schneider LC1E0910M5 is a compact, efficient, and reliable contactor for motor control and electrical switching applications. With its 9A (AC-3) rating, 3P (3NO) main contacts, 220V AC coil, and 1NO auxiliary contact, it is ideal for industrial automation, small motor control, and HVAC applications, ensuring safe and long-lasting operation.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| range of product | Easy TeSys Control |
| product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 9 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50 Hz |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...400 V AC 50/60 Hz 4 kW at 415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 5.5 kW at 660...690 V AC 50/60 Hz |
|---|---|
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 25 A (at 55 °C) for power circuit |
| Irms rated making capacity | 90 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 72 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit 61 A 40 °C - 60 s for power circuit 30 A 40 °C - 600 s for power circuit |
| Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 20 A gG at <= 690 V coordination type 1 for power circuit |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 0.2 W AC-3 1.6 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 1400000 cycles AC-3 150000 cycles AC-1 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz |
| Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W for control circuit |
| Operating time | 12...22 ms on closing 4...19 ms on opening |
| Maximum operating rate | 1800 cyc/h 60 °C |
| Connections - terminals | Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end |
| Tightening torque | Power circuit: 1.2 N.m Control circuit: 1.2 N.m |
| Auxiliary contact composition | 1 NO |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| mounting support | Plate DIN rail |
| Standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 |
|---|---|
| Product certifications | CE EAC |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 80 mm |
| net weight | 0.3 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.700 cm |
| Package 1 Width | 5.000 cm |
| Package 1 Length | 7.500 cm |
| Package 1 Weight | 339.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.932 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 576 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 215.412 kg |
| Warranty | 18 months |
|---|
Main documents
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1E0910M5 |
|
Instruction sheet
|
Download |
| Catalog | Download |
|
Environmental disclosure
|
Download |
| CAD Files | Download |
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1E0910M5 |
|
Instruction sheet |
Download |
| Catalog | Download |
|
Environmental disclosure |
Download |
| CAD Files | Download |
Reviews