Description

Schneider LRD08 | TeSys LRD thermal overload relays – 2.5…4 A – class 10A

  1. Schneider LRD08 | TeSys LRD Thermal Overload Relay, 2.5-4A, Class 10A

    1. Overview

    The Schneider LRD08 is a thermal overload relay from the TeSys LRD series, designed to protect motors from overloads and phase loss. It operates within a 2.5 to 4A current range and follows the Class 10A tripping standard, ensuring quick and reliable motor protection.

    2. Key Features

    • Brand: Schneider Electric
    • Series: TeSys LRD
    • Model: LRD08
    • Type: Thermal Overload Relay
    • Current Range: 2.5 – 4A
    • Trip Class: 10A
    • Phase Failure Protection: Yes
    • Reset Mode: Manual and Automatic
    • Mounting: Directly attaches to TeSys D contactors
    • Auxiliary Contacts: 1 NO + 1 NC

    3. Benefits

    • Reliable Protection: Prevents motor damage due to overload or phase failure.
    • Fast Tripping Response: Class 10A ensures quick shutdown during faults.
    • Seamless Integration: Designed to work with TeSys D contactors for easy installation.
    • Compact & Efficient: Space-saving design for control panels.
    • Dual Reset Options: Offers both manual and automatic reset functionality.

    4. Applications

    • Small Industrial Motors: Used in pumps, fans, and conveyors.
    • HVAC Systems: Protects motors in heating and cooling applications.
    • Automation Systems: Ensures safe operation of industrial machinery.
    • Water Treatment Plants: Prevents overheating in small motor-driven pumps.

    5. Conclusion

    The Schneider LRD08 TeSys LRD Thermal Overload Relay provides reliable, efficient, and quick protection for small motors operating in the 2.5-4A range. Its easy integration, compact design, and dependable performance make it an ideal choice for various industrial and commercial applications

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys TeSys Deca
Product name TeSys LRD TeSys Deca
Product or component type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product compatibility LC1D12 LC1D09 LC1D25 LC1D38 LC1D32 LC1D18
Network type AC DC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 2.5…4 A
[Ui] rated insulation voltage Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1
Complementary
Network frequency 0...400 Hz
Mounting support Plate, with specific accessories Rail, with specific accessories Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 3 A at 120 V AC-15 for signalling circuit 0.22 A at 125 V DC-13 for signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit 4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop Blue push-button: reset
Temperature compensation -20…60 °C
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals Power circuit: 1.7 N.m - on screw clamp terminals
Height 66 mm
Width 45 mm
Depth 70 mm
Net weight 0.124 kg
Environment
Climatic withstand conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6 Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
Product certifications IEC UL CSA CCC EAC BV RINA DNV-GL LROS (Lloyds register of shipping) ATEX INERIS UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 7.800 cm
Package 1 Length 8.900 cm
Package 1 Weight 140.900 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 3.720 kg
Contractual warranty
Warranty 18 months

Main documents

Main documents

Datasheet Download Datasheet
Product datasheet LRD08
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Main documents

Datasheet Download Datasheet
Product datasheet LRD08
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Reviews (0)

Be the first to review “Schneider LRD08 | TeSys LRD thermal overload relays – 2.5…4 A – class 10A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare