Schneider RM17TA00 Relay | Multifunction control relay RM17-TA – range 183..528 V AC
Schneider RM17TA00 Relay
Description
Schneider RM17TA00 Relay: Revolutionizing Control Systems
Product Overview: Schneider RM17TA00 Relay
The Schneider RM17TA00 is a multifunction control relay from the RM17-TA series, designed for voltage monitoring in electrical systems. It ensures safe operation by detecting overvoltage and undervoltage conditions, making it ideal for use in both industrial and commercial electrical panels.
Key Features
-
Product Type: Voltage monitoring relay
-
Model: RM17TA00
-
Series: RM17-TA
-
Monitoring Range: 183 to 528 V AC (three-phase)
-
Control Supply Voltage: Supplied directly from monitored voltage
-
Output: 1 changeover contact (1 C/O – SPDT)
-
Mounting: DIN rail
-
Measurement Type: True RMS
-
Detection: Overvoltage, undervoltage, phase failure, and phase sequence
-
Adjustable Thresholds and Delay Times
-
LED Indicators: Status display for power and fault conditions
-
IP Rating: IP20 (terminals), IP50 (front face)
Functions
-
Overvoltage Monitoring
Detects and trips when voltage exceeds the upper limit. -
Undervoltage Monitoring
Detects and trips when voltage drops below the lower limit. -
Phase Failure Detection
Detects loss of any of the three phases. -
Phase Sequence Detection
Ensures the correct order of phases (L1-L2-L3). -
Adjustable Delay on Trip and Reset
Helps to avoid nuisance tripping during brief disturbances.
Applications
-
Protection of motors and compressors
-
Monitoring incoming power supply quality
-
Industrial automation panels
-
Commercial and residential electrical installations
-
HVAC systems and elevators
Benefits
-
Protects equipment from voltage abnormalities
-
Detects critical faults like phase loss and wrong sequence
-
Simplifies wiring with built-in power supply from measured voltage
-
Compact DIN rail design for easy installation
-
High reliability with true RMS measurement
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Multifunction control relay |
| Product or component type | 3-phase control relay |
| Relay name | RM17TA |
| Relay monitored parameters | Asymmetry Phase sequence Phase failure detection |
| Measurement range | 208...480 V AC |
| time delay | Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Output contacts | 1 C/O |
| Nominal output current | 5 A |
| Contacts type and composition | 1 C/O |
| [Uc] control circuit voltage | 208...480 V |
| Product specific application | For 3-phase supply |
| [Un] rated nominal voltage | , self-powered |
|---|---|
| Supply voltage limits | 183…528 V AC |
| Reset time | 1500 ms time delay |
| Maximum switching voltage | 250 V AC 250 V DC |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC 5 A DC |
| Control circuit voltage limits | - 12 % + 10 % Un |
| Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Measurement voltage limits | 183…528 V AC |
| Hysteresis | 2 % |
| delay at power up | 650 ms |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Voltage range | 208...480 V phase to phase |
| Adjustment of asymmetry threshold | 5...15 % of Un selected |
| Repeat accuracy | 0.5 % for input and measurement circuit 3 % for time delay |
| Measurement error | < 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation |
| Phase failure sensitivity | 0.7 Un |
| Response time | < 200 ms (in the event of a fault) |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
| Safety reliability data | MTTFd = 502.2 years B10d = 470000 |
| Width | 17.5 mm |
| Net weight | 0.13 kg |
| Control type | Without test button |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to IEC 61000-6-2 |
|---|---|
| Standards | IEC 60255-1 |
| Product certifications | GOST CSA GL C-Tick UL |
| Marking | CE |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
| Non-dissipating shock wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.800 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.600 cm |
| Package 1 Weight | 92.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.700 kg |
| Warranty | 18 months |
|---|
Reviews