Schneider RM17UAS15 Relay | Voltage control relay RM17-U – range 65..260 V AC
Schneider RM17UAS15 Relay
Description
Schneider RM17UAS15 Relay
In the realm of electrical engineering, precision and reliability are paramount. Schneider Electric, a global leader in energy management and automation, introduces the RM17UAS15 Relay, a cutting-edge solution designed to meet the diverse needs of modern electrical systems.
Understanding the Functionality of RM17UAS15 Relay
What is a Relay?
A relay is an electromechanical device that allows a low-power signal to control a higher-power circuit. It acts as a switch, enabling the control of multiple circuits with a single signal.
Applications of RM17UAS15 Relay
it finds extensive applications in various industries, including manufacturing, automotive, and telecommunications. It is utilized in motor control, lighting systems, and power distribution networks.
Importance of RM17UAS15 Relay in Electrical Systems
it plays a crucial role in ensuring the safety and efficiency of electrical systems. By providing reliable switching capabilities, it helps prevent electrical failures and ensures smooth operation.
Key Features of RM17UAS15 Relay
Accuracy and Precision
The RM17UAS15 Relay boasts unparalleled accuracy, allowing precise control over electrical circuits. Its high-quality construction ensures dependable performance in diverse operating conditions.
Versatility in Applications
From industrial automation to building management systems, it offers unmatched versatility. Its flexible design accommodates a wide range of voltage and current requirements, making it suitable for various applications.
Durability and Longevity
Built to withstand harsh environments, it is engineered for durability and longevity. Its rugged construction and robust components ensure reliable operation even in challenging industrial settings.
Easy Installation and Maintenance
Designed for ease of installation, the RM17UAS15 Relay simplifies the integration process, reducing downtime and labor costs. Additionally, its modular design facilitates quick and hassle-free maintenance, minimizing operational disruptions.
Technical Specifications of RM17UAS15 Relay
Voltage Ratings
it supports a wide range of voltage ratings, ranging from 12V to 240V, accommodating various electrical systems and applications.
Current Ratings
With configurable current ratings up to 15A, the RM17UAS15 Relay delivers exceptional performance, ensuring efficient power distribution and control.
Contact Configuration
Featuring SPDT (Single-Pole Double-Throw) contact configuration, it offers versatile switching capabilities, enabling seamless integration into diverse circuit layouts.
Response Time
it boasts rapid response times, minimizing latency and ensuring timely activation and deactivation of connected loads.
Advantages of Using RM17UAS15 Relay
Enhanced Safety
By providing reliable overcurrent and overload protection, it enhances the safety of electrical systems, mitigating the risk of equipment damage and personnel injury.
Improved Efficiency
With its efficient switching capabilities, it optimizes energy usage, reducing operational costs and environmental impact.
Cost-Effectiveness
The RM17UAS15 Relay offers excellent value for money, combining high performance with competitive pricing, making it an ideal choice for budget-conscious consumers.
How to Install RM17UAS15 Relay
Precautionary Measures
Before installing it, it is essential to adhere to all safety precautions outlined in the user manual. This includes wearing appropriate protective gear and de-energizing the electrical circuit.
Step-by-Step Installation Guide
- Prepare the Installation Site: Select a suitable location for mounting the relay, ensuring adequate ventilation and accessibility.
- Mount the Relay: Securely mount the RM17UAS15 Relay using the provided mounting hardware, ensuring proper alignment and clearance.
- Connect the Wiring: Carefully connect the input and output wiring to the relay terminals, following the wiring diagram provided in the user manual.
- Test the Relay: After installation, perform a functional test to verify proper operation and ensure that all connections are secure.
- Finalize Installation: Once the relay is tested and confirmed operational, finalize the installation by securing any loose wiring and closing the enclosure.
Maintenance Tips for RM17UAS15 Relay
Regular Inspections
Periodic inspections are essential to ensure the optimal performance it. Inspect the relay for signs of damage or wear, and replace any faulty components as needed.
Cleaning Procedures
Keep the relay and its surrounding environment clean and free from dust, debris, and moisture. Use a soft brush or compressed air to remove any contaminants that may affect performance.
Troubleshooting Common Issues
In the event of a malfunction, refer to the troubleshooting guide provided in the user manual. Identify the root cause of the issue and take appropriate corrective actions to restore normal operation.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Voltage control relay |
| Product or component type | Voltage control relay |
| Product specific application | For single-phase and DC supply |
| Relay name | RM17UAS |
| Relay monitored parameters | Overvoltage or undervoltage detection |
| time delay | Adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Measurement range | 65...260 V AC/DC |
| Contacts type and composition | 1 C/O |
| Reset time | 1500 ms time delay |
|---|---|
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Supply voltage limits | 50…270 V AC/DC |
| Power consumption in VA | 0…3 VA AC |
| Maximum power consumption in W | 1 W DC |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Immunity to microbreaks | 20 ms |
| Output contacts | 1 C/O |
| Nominal output current | 5 A |
| Hysteresis | 5…20 % of threshold setting |
| Measurement accuracy | +/- 10 % of the full scale value |
| Polarity | Non reversible polarity on DC supply |
| delay at power up | 1000 ms DC 500 ms AC |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 1 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation |
| Quality labels | CE |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Overvoltage category | III conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1 |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
| [Un] rated nominal voltage | , self-powered |
| Control type | Without test button |
| Width | 17.5 mm |
| Net weight | 0.08 kg |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|---|---|
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 5 gn conforming to IEC 60068-2-27 |
| Standards | IEC 60255-6 |
| Product certifications | GL UL GOST CSA C-Tick |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
| Non-dissipating shock wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.500 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 81.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.809 kg |
| Warranty | 18 months |
|---|
Reviews