Schneider RM35UA13MW Relay | Multifunction voltage control relay RM35-U – range 15..600 V
Schneider RM35UA13MW Relay
Description
Schneider RM35UA13MW Relay
it is an essential component in various electrical systems, renowned for its reliability and performance. This article aims to explore the features, applications, installation guide, troubleshooting, and comparison of the Schneider RM35UA13MW Relay, providing valuable insights for professionals and enthusiasts alike.
Key Features of Schneider RM35UA13MW Relay
The it boasts several key features that make it a preferred choice in the industry. With its compact design and advanced technology, this relay offers:
- Precision Monitoring: The relay provides accurate monitoring of essential electrical parameters, ensuring optimal performance and safety.
- Wide Voltage Range: It operates within a wide voltage range, making it suitable for various electrical applications.
- Reliable Operation: Built with high-quality materials, the relay ensures reliable operation even in harsh environments.
- User-Friendly Interface: With an intuitive interface, it allows for easy configuration and monitoring.
Applications of Schneider RM35UA13MW Relay
The Schneider RM35UA13MW Relay finds extensive applications across different industries and sectors, including:
- Industrial Automation: It is widely used in industrial automation systems for monitoring and controlling electrical parameters.
- Power Distribution: In power distribution networks, the relay ensures efficient power management and protection against faults.
- Building Management: It plays a crucial role in building management systems, providing real-time monitoring of electrical parameters.
- Renewable Energy: The relay is instrumental in renewable energy systems, ensuring efficient operation and grid integration.
Installation Guide for Schneider RM35UA13MW Relay
Installing the Schneider RM35UA13MW Relay is straightforward, following these steps:
- Prepare the Mounting Surface: Ensure that the mounting surface is clean and free from any debris.
- Mount the Relay: Securely mount the relay using appropriate screws or fasteners.
- Connect the Wiring: Connect the wiring according to the specified terminal connections, ensuring proper insulation.
- Configure Settings: Use the user-friendly interface to configure the relay settings as per the application requirements.
- Test the Operation: Once installed, perform a thorough test to verify the operation and functionality of the relay.
Troubleshooting Common Issues
Despite its reliability, the Schneider RM35UA13MW Relay may encounter common issues such as:
- Overheating: Check for any obstructions or inadequate ventilation around the relay.
- Faulty Connections: Inspect the wiring connections for any loose or damaged terminals.
- Parameter Drift: Calibrate the relay settings to ensure accurate monitoring and control.
Comparison with Other Relays
Compared to other relays in the market, the Schneider RM35UA13MW Relay offers several advantages, including:
- Enhanced Performance: It provides precise monitoring and reliable operation, surpassing many competitors.
- Versatility: With its wide voltage range and flexible configuration options, it caters to diverse applications.
- Durability: Built with robust materials, it ensures long-term durability and stability.
However, like any product, it also has certain limitations, such as higher initial cost compared to some alternatives.
Conclusion
In conclusion, the Schneider RM35UA13MW Relay stands out as a reliable and versatile solution for monitoring and controlling electrical parameters in various applications. With its advanced features, user-friendly interface, and robust construction, it offers unmatched performance and durability. Whether in industrial automation, power distribution, building management, or renewable energy systems, this relay proves to be an indispensable asset. Invest in the Schneider RM35UA13MW Relay for enhanced efficiency, safety, and peace of mind in your electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Multifunction voltage control relay |
| Product or component type | Voltage control relay |
| Relay name | RM35UA |
| Relay monitored parameters | Overvoltage or undervoltage detection |
| time delay | Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Measurement range | 15...600 V AC/DC |
| Contacts type and composition | 2 C/O |
| Reset time | 1500 ms time delay |
|---|---|
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| operating voltage tolerance | - 15 % + 10 % Un |
| Supply voltage limits | 20.4…264 V AC/DC |
| Power consumption in VA | 0…3.5 VA AC |
| Maximum power consumption in W | 0.6 W DC |
| Control circuit frequency | 40...70 Hz +/- 10 % |
| Immunity to microbreaks | 10 ms |
| Resistance across terminals | 150 mOhm at E1-M terminals 300 mOhm at E2-M terminals 600 mOhm at E3-M terminals |
| Output contacts | 2 C/O |
| Nominal output current | 5 A |
| Hysteresis | 5…50 % of threshold setting |
| Measurement accuracy | +/- 10 % of the full scale value |
| Polarity | Non reversible polarity on DC supply |
| delay at power up | 600 ms |
| Maximum measuring cycle | 30 ms measurement cycle as true rms value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 2 % for time delay |
| Measurement error | +/- 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation |
| Sensitivity scale | 15...150 V E1-M terminals 30...300 V E2-M terminals 60...600 V E3-M terminals |
| Threshold setting | 10...100 % |
| Quality labels | CE |
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Overvoltage category | III conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 600 V conforming to IEC 60664-1 |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Safety reliability data | B10d = 290000 MTTFd = 308.2 years |
| Control type | Without test button |
| Width | 35 mm |
| Net weight | 0.08 kg |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|---|---|
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 5 gn conforming to IEC 60068-2-27 |
| Standards | IEC 60255-6 |
| Product certifications | GOST UL GL C-Tick CSA |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Directives | 73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
| Non-dissipating shock wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.5 cm |
| Package 1 Width | 7.8 cm |
| Package 1 Length | 9.6 cm |
| Package 1 Weight | 136.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 7.271 kg |
| Warranty | 18 months |
|---|
Main documents
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | RM35UA13MW |
|
Instruction sheet
|
Download |
| Catalog | Download |
|
Environmental disclosure
|
Download |
| CAD Files | Download |
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | RM35UA13MW |
|
Instruction sheet |
Download |
| Catalog | Download |
|
Environmental disclosure |
Download |
| CAD Files | Download |
Reviews