Schneider C10F6TM100 Compact | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 100A, 4 poles 3d
Schneider C10F6TM100 Compact
Description
Schneider C10F6TM100 Compact
Introduction
Circuit breakers serve as crucial components in electrical systems, safeguarding them from overloads and short circuits. Schneider Electric, a leading provider of energy management solutions, offers the Schneider C10F6TM100 Compact. This guide provides an in-depth exploration of this circuit breaker, including its features, benefits, and applications.
Understanding the Schneider C10F6TM100 Compact
Overview of Schneider C10F6TM100 Compact
it is a reliable circuit breaker designed to provide efficient protection for electrical circuits. It is part of Schneider Electric’s Compact range, known for its performance and durability.
Key Features and Specifications
- Rated Current: Up to 100A
- Breaking Capacity: High-breaking capacity for enhanced protection
- Compact Design: Space-saving design suitable for various installations
- Technology: Advanced tripping mechanism for rapid response
- Compliance: Meets international standards for safety and quality
Design and Construction
Quality Build
it is built with high-quality materials to ensure durability and longevity. Its robust construction allows it to withstand harsh environmental conditions, making it suitable for a wide range of applications.
Compact Design Advantages
With its compact design, it offers significant advantages, including easy installation in space-constrained environments without compromising performance.
Material Composition
The circuit breaker is constructed from premium materials chosen for their resilience and reliability. These materials contribute to the overall durability and effectiveness of it.
Functionality and Performance
Operational Mechanism
it operates by interrupting the electrical current when an overload or short circuit is detected. Its advanced tripping mechanism ensures a swift response, minimizing the risk of electrical hazards.
Performance Metrics
Equipped with a high-breaking capacity and precise tripping mechanism, the C10F6TM100 Compact delivers exceptional performance, meeting the stringent demands of industrial and commercial applications.
Reliability and Efficiency
Schneider Electric’s commitment to reliability is evident in the C10F6TM100 Compact, offering consistent performance and energy efficiency. Its reliable operation minimizes downtime and reduces energy consumption.
Installation Process
Step-by-Step Installation Guide
- Preparation: Ensure all safety precautions are in place before commencing installation.
- Mounting: Securely mount the circuit breaker in the designated location.
- Wiring: Connect the electrical wires according to the provided guidelines.
- Testing: Conduct thorough testing post-installation to verify proper functionality.
Safety Measures During Installation
- Always disconnect the power supply before initiating installation.
- Use insulated tools to prevent electrical accidents.
- Adhere to all installation instructions provided by Schneider Electric.
Necessary Tools
- Screwdrivers
- Wire cutters/strippers
- Insulation tape
- Multimeter
Applications of Schneider C10F6TM100 Compact
Industrial Applications
In industrial settings, it protects critical machinery and equipment from electrical faults, ensuring uninterrupted operations and safety.
Commercial Applications
For commercial buildings, this circuit breaker offers reliable protection for electrical installations, including lighting, HVAC systems, and more.
Residential Applications
Even in residential settings, the C10F6TM100 Compact can be utilized to safeguard home electrical systems, providing peace of mind to homeowners.
Benefits of Using Schneider C10F6TM100 Compact
Enhanced Safety Features
The primary benefit of the C10F6TM100 Compact is its enhanced safety features, which help prevent electrical hazards and protect both equipment and personnel.
Energy Efficiency
Designed for energy efficiency, the C10F6TM100 Compact contributes to lower energy consumption and reduced operating costs over time.
Cost Savings
With its durable construction and reliable performance, the C10F6TM100 Compact offers long-term cost savings, making it a cost-effective solution for electrical protection.
Comparison with Other Circuit Breakers
C10F6TM100 Compact vs. Traditional Models
Compared to traditional circuit breakers, it stands out for its superior performance, compact design, and advanced features, providing optimal protection and efficiency.
Competitor Analysis
When compared to competitors, Schneider C10F6TM100 Compact excels in terms of build quality, reliability, and comprehensive support, making it a preferred choice for professionals.
Maintenance and Troubleshooting
Maintenance Tips
- Regularly inspect for signs of wear or damage.
- Ensure all connections are secure and tight.
- Perform periodic testing to ensure proper functionality.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100F |
| Product or component typee | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 100 A at 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 8.8 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.000 cm |
| Package 1 Width | 15.000 cm |
| Package 1 Length | 19.000 cm |
| Package 1 Weight | 2.309 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 15.884 kg |