Schneider C10H3TM100 Compact | Circuit breaker, ComPacT NSX100H, 70kA/415VAC, 3 poles, TMD trip unit 100A
Schneider C10H3TM100 Compact
Description
Schneider C10H3TM100 Compact
Introduction
In today’s advanced electrical systems, it stands out as a reliable and efficient solution. This article delves into the features, benefits, and applications of the Schneider C10H3TM100 Compact, explaining why it is a preferred choice for various electrical installations.
Understanding the Schneider C10H3TM100 Compact
Definition and Purpose
it is a circuit breaker designed to protect electrical circuits from overloads, short circuits, and other faults. Its main purpose is to ensure the safety and reliability of electrical systems, safeguarding both equipment and personnel from potential hazards.
Key Features and Specifications
Key features of the Schneider C10H3TM100 Compact include:
- High Breaking Capacity: Capable of interrupting high fault currents.
- Compact Design: Space-saving without compromising performance.
- Adjustable Protection Settings: Customizable to meet specific requirements.
- Ease of Installation: User-friendly design simplifies setup.
- Durable Construction: Built to withstand various environmental demands.
Benefits of Using Schneider C10H3TM100 Compact
Enhanced Safety Measures
Safety is a top priority in electrical systems, and it excels in this regard with its advanced protection mechanisms. It quickly detects and responds to faults, reducing the risk of electrical hazards and ensuring the safety of both personnel and equipment.
Reliability and Durability
it is designed for long-term use, offering durable construction and reliable performance. It can endure the rigors of various applications, providing consistent protection and peace of mind to users.
Energy Efficiency
In an era focused on energy conservation, it stands out for its energy efficiency. It optimizes energy use, helping to reduce waste and lower electricity bills, contributing to overall energy conservation efforts.
Applications of Schneider C10H3TM100 Compact
Industrial Settings
In industrial environments, where electrical loads can be substantial and complex, the Schneider C10H3TM100 Compact offers reliable protection and efficient energy management. It is ideal for machinery, equipment, and production lines, ensuring uninterrupted operations.
Commercial Installations
Commercial buildings, such as offices, malls, and hotels, benefit from the Schneider C10H3TM100 Compact’s compact design and advanced protection features. It helps maintain the integrity of electrical systems, supporting business continuity and protecting valuable assets.
Residential Use
Even in residential settings, the Schneider C10H3TM100 Compact proves invaluable. Its high breaking capacity and customizable settings make it suitable for protecting household electrical systems, providing peace of mind to homeowners.
Installation Process
Pre-installation Preparations
Before installing the Schneider C10H3TM100 Compact, it is essential to conduct a thorough assessment of the electrical system. Ensure that all necessary tools and materials are available, and safety protocols are followed.
Step-by-Step Installation Guide
- Turn Off Power: Disconnect the main power supply to prevent accidents.
- Mount the Circuit Breaker: Secure the Schneider C10H3TM100 Compact in its designated location, following the manufacturer’s instructions.
- Connect Wiring: Wire the circuit breaker according to the provided diagram, ensuring proper connections.
- Adjust Settings: Customize the protection settings as per the requirements of the electrical system.
- Test the Installation: Conduct thorough testing to ensure the circuit breaker is functioning correctly.
- Restore Power: Once the installation is verified, restore the power supply and monitor for any abnormalities.
Maintenance Tips
Regular Checks
Regular maintenance is essential to ensure the optimal performance of the Schneider C10H3TM100 Compact. Conduct routine checks to inspect for loose connections, signs of wear, or any other issues that may arise.
Troubleshooting Common Issues
If any issues are detected, refer to the troubleshooting guide provided by Schneider Electric. Common problems can often be resolved by adjusting settings or replacing faulty components.
Comparison with Competitors
Performance Evaluation
When compared to competitors, the Schneider C10H3TM100 Compact excels in terms of performance, offering reliable protection and efficient operation. Its high breaking capacity and advanced features set it apart from similar products on the market.
Cost Analysis
While the initial cost of the Schneider C10H3TM100 Compact may be higher than some alternatives, its long-term durability and reliability often result in cost savings. Reduced maintenance needs and enhanced safety contribute to its overall value.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100H |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 8.8 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.05 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.784 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 12.882 kg |
Reviews
There are no reviews yet.