Schneider C25B32D250 ComPacT | Product picture Schneider Electric 1 videos Circuit breaker ComPacT NSX250B, 25kA at 415VAC, MicroLogic 2.2 trip unit 250A, 3 poles 3d
Schneider C25B32D250 ComPacT
Description
Schneider C25B32D250 ComPacT
Introduction
Exploring the Schneider C25B32D250 ComPacT Breaker
Schneider Electric, a global leader in electrical equipment, introduces it breaker, designed to deliver exceptional performance and reliability in electrical systems. In this comprehensive guide, we dive into the features, benefits, and applications of this innovative product.
Understanding Schneider Electric
A Legacy of Innovation
Schneider Electric has a rich history of innovation and excellence in the electrical industry. With a focus on sustainability and technological advancement, the company continues to redefine standards and drive progress in the field of electrical engineering.
Introducing the C25B32D250 ComPacT Breaker
Superior Performance and Efficiency
it is engineered to provide unmatched performance and efficiency in a compact design. With advanced circuitry and robust construction, it offers reliable protection against overloads and short circuits, ensuring the safety and stability of electrical systems.
Key Features
- Compact design for space-saving installation
- High breaking capacity for enhanced protection
- Easy installation and maintenance
- Compatibility with a wide range of accessories
Applications
Versatility Across Industries
From residential buildings to industrial facilities, it breaker is suitable for various applications. Its versatility and reliability make it an ideal choice for:
- Residential complexes
- Commercial establishments
- Manufacturing plants
- Data centers
Benefits of Choosing Schneider
Trusted Quality and Reliability
Schneider Electric is synonymous with quality and reliability. By selecting it breaker, customers can trust that they are investing in a product that meets the highest standards of performance and durability.
Enhanced Safety and Protection
Safety is paramount in any electrical system. The C25B32D250 ComPacT breaker ensures optimal protection against faults and abnormalities, reducing the risk of electrical hazards and minimizing downtime due to equipment failure.
Cost-Effective Solution
In addition to its superior performance, the C25B32D250 ComPacT breaker offers cost savings through its efficient operation and low maintenance requirements. Its durable design and long-term reliability translate to lower total cost of ownership for customers.
Installation and Maintenance
Seamless Integration and Ease of Use
Installing the C25B32D250 ComPacT breaker is straightforward, thanks to its compact design and user-friendly features. With minimal wiring and assembly required, electricians can complete installations quickly and efficiently, reducing downtime and disruptions.
Simple Maintenance and Servicing
Routine maintenance is essential to ensure the optimal performance of electrical equipment. The C25B32D250 ComPacT breaker is designed for easy maintenance, with accessible components and intuitive diagnostics that streamline servicing and minimize downtime.
Conclusion
Embracing Innovation with Schneider Electric
The Schneider C25B32D250 ComPacT breaker exemplifies the company’s commitment to innovation and excellence. With its advanced features, reliable performance, and versatile applications, it sets a new standard for electrical protection and efficiency.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX250B |
| Product or component typee | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 250 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | MicroLogic 2.2 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 17.6 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 250 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 100...250 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 3000 A |
| earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.700 cm |
| Package 1 Width | 14.800 cm |
| Package 1 Length | 19.300 cm |
| Package 1 Weight | 1.948 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 14.092 kg |