Schneider LR2K0314 | TeSys K – differential thermal overload relays – 5.5…8 A – class 10A
Description
Schneider LR2K0314 | TeSys K – differential thermal overload relays – 5.5…8 A – class 10A
Schneider LR2K0314 | Thermal Overload Relay, TeSys K – 5.5 to 8 A, Class 10A
The Schneider LR2K0314 is a differential thermal overload relay from the TeSys K series, tailored to protect motors from overloads, phase loss, and phase imbalance. With an adjustable current range of 5.5 to 8 A, it is ideal for low to mid-power motor applications.
General Information:
-
Brand: Schneider Electric
-
Series: TeSys K
-
Model Number: LR2K0314
-
Product Type: Thermal Overload Relay
-
Adjustable Current Range: 5.5 – 8 A
-
Trip Class: 10A (standard response time for motor protection)
-
Mounting Style: Direct mount on TeSys K contactors (LC1K series)
Key Features:
-
Differential Protection: Detects and protects against phase failure and current imbalance
-
Current Adjustment Dial: Precise tuning to match motor rating
-
Reset Options: Manual and automatic reset selector
-
Auxiliary Contacts: Includes 1 NO + 1 NC for signaling or interlocking
-
Compact Design: Saves space in panels and enclosures
Technical Specifications:
-
Current Range: 5.5 to 8 A
-
Trip Class: 10A
-
Reset Options: Manual / Automatic
-
Auxiliary Contacts: 1 Normally Open + 1 Normally Closed
-
Mounting: Direct on LC1K contactors
-
Standard Compliance: IEC 60947-4-1, IEC 60947-5-1
Applications:
-
HVAC systems
-
Industrial motor starters
-
Small conveyor systems
-
Pumps, blowers, and fans
-
Panel builders and OEM machinery
Benefits:
-
Effective and reliable motor protection
-
Easy setup and maintenance
-
Compatible with Schneider LC1K series contactors
-
Enhances system uptime with fast and safe fault response
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys |
|---|---|
| Product name | TeSys LRK |
| Product or component type | Differential thermal overload relay |
| Device short name | LR2K |
| Relay application | Motor protection |
| Product compatibility | LC7K LC1K LP4K LP1K |
| Network type | DC AC |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 5.5…8 A |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to BS 4941 Power circuit: 690 V conforming to IEC 60947 Power circuit: 750 V conforming to VDE 0110 group C Power circuit: 600 V conforming to CSA C22.2 No 14 |
| Network frequency | <= 400 Hz |
|---|---|
| Mounting support | Under contactor Plate, with specific accessories Rail, with specific accessories |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 6 A for signalling circuit |
| [Ue] rated operational voltage | <= 690 V for power circuit 690 V AC AC-15 for signalling circuit 250 V DC DC-13 for signalling circuit |
| Associated fuse rating | 6 A gG for signalling circuit conforming to VDE 0660 6 A gG for signalling circuit conforming to IEC 60947 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Power dissipation per pole | 2 W |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Local signalling | Trip indicator (yellow) |
| Control type | Red push-button: trip test function Blue push-button: stop and manual reset selector switch: manual or automatic reset |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| height | 58 mm |
| Width | 45 mm |
| Depth | 65 mm |
| Net weight | 0.145 kg |
| Standards | VDE 0660 NF C 63-650 IEC 60947 BS 4941 |
|---|---|
| product certifications | UL CSA UKCA |
| Protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947 |
| Ambient air temperature for storage | -40…70 °C |
| Operating altitude | 2000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Mechanical robustness | Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.100 cm |
| Package 1 Length | 8.200 cm |
| Package 1 Weight | 159.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 41 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.756 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : LR2K0314
Main Document
Data Sheet : LR2K0314
Reviews (0)
Recommended for you
-
0
Schneider LR2K0307 | TeSys K – differential thermal overload relays – 1.2…1.8 A – class 10A
-
0
Reviews