Description

Schneider LR2K0314 | TeSys K – differential thermal overload relays – 5.5…8 A – class 10A

Schneider LR2K0314 | Thermal Overload Relay, TeSys K – 5.5 to 8 A, Class 10A

The Schneider LR2K0314 is a differential thermal overload relay from the TeSys K series, tailored to protect motors from overloads, phase loss, and phase imbalance. With an adjustable current range of 5.5 to 8 A, it is ideal for low to mid-power motor applications.

General Information:

  • Brand: Schneider Electric

  • Series: TeSys K

  • Model Number: LR2K0314

  • Product Type: Thermal Overload Relay

  • Adjustable Current Range: 5.5 – 8 A

  • Trip Class: 10A (standard response time for motor protection)

  • Mounting Style: Direct mount on TeSys K contactors (LC1K series)

Key Features:

  • Differential Protection: Detects and protects against phase failure and current imbalance

  • Current Adjustment Dial: Precise tuning to match motor rating

  • Reset Options: Manual and automatic reset selector

  • Auxiliary Contacts: Includes 1 NO + 1 NC for signaling or interlocking

  • Compact Design: Saves space in panels and enclosures

Technical Specifications:

  • Current Range: 5.5 to 8 A

  • Trip Class: 10A

  • Reset Options: Manual / Automatic

  • Auxiliary Contacts: 1 Normally Open + 1 Normally Closed

  • Mounting: Direct on LC1K contactors

  • Standard Compliance: IEC 60947-4-1, IEC 60947-5-1

Applications:

  • HVAC systems

  • Industrial motor starters

  • Small conveyor systems

  • Pumps, blowers, and fans

  • Panel builders and OEM machinery

Benefits:

  • Effective and reliable motor protection

  • Easy setup and maintenance

  • Compatible with Schneider LC1K series contactors

  • Enhances system uptime with fast and safe fault response

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys
Product name TeSys LRK
Product or component type Differential thermal overload relay
Device short name LR2K
Relay application Motor protection
Product compatibility LC7K LC1K LP4K LP1K
Network type DC AC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 5.5…8 A
[Ui] rated insulation voltage Power circuit: 690 V conforming to BS 4941 Power circuit: 690 V conforming to IEC 60947 Power circuit: 750 V conforming to VDE 0110 group C Power circuit: 600 V conforming to CSA C22.2 No 14
Complementary
Network frequency <= 400 Hz
Mounting support Under contactor Plate, with specific accessories Rail, with specific accessories
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 6 A for signalling circuit
[Ue] rated operational voltage <= 690 V for power circuit 690 V AC AC-15 for signalling circuit 250 V DC DC-13 for signalling circuit
Associated fuse rating 6 A gG for signalling circuit conforming to VDE 0660 6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage 6 kV
Power dissipation per pole 2 W
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Local signalling Trip indicator (yellow)
Control type Red push-button: trip test function Blue push-button: stop and manual reset selector switch: manual or automatic reset
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
height 58 mm
Width 45 mm
Depth 65 mm
Net weight 0.145 kg
Environment
Standards VDE 0660 NF C 63-650 IEC 60947 BS 4941
product certifications UL CSA UKCA
Protective treatment TC conforming to IEC 60068 TC conforming to DIN 50016
IP degree of protection IP2X conforming to IEC 60529
Ambient air temperature for operation -20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947
Ambient air temperature for storage -40…70 °C
Operating altitude 2000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Mechanical robustness Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 cm
Package 1 Width 7.100 cm
Package 1 Length 8.200 cm
Package 1 Weight 159.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 41
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 6.756 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : LR2K0314

Main Document

Data Sheet : LR2K0314

Reviews (0)

Be the first to review “Schneider LR2K0314 | TeSys K – differential thermal overload relays – 5.5…8 A – class 10A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products