Schneider LAG8N203P | Auxiliary contact block,TeSys Giga contactor,2NO,lateral face side mounting,push-in terminals L1/R1
Schneider LAG8N203P | Auxiliary contact block,TeSys Giga contactor,2NO,lateral face side mounting,push-in terminals L1/R1
Description
Schneider LAG8N203P | Auxiliary contact block,TeSys Giga contactor,2NO,lateral face side mounting,push-in terminals L1/R1
The Schneider LAG8N203P is an advanced auxiliary contact block specifically designed for use with TeSys Giga contactors. This block features 2 normally open (NO) contacts and is mounted on the lateral face side of the contactor, making it ideal for applications that require efficient signaling and control. The Push-In Terminal (PIT) technology ensures a tool-free, quick, and secure installation.
General Information:
-
Brand: Schneider Electric
-
Series: TeSys Giga
-
Product Code: LAG8N203P
-
Function: Auxiliary Contact Block
-
Contact Configuration: 2 NO (normally open)
-
Mounting Position: Lateral face side (L1/R1 side)
-
Terminal Type: Push-in (spring clamp) terminals
-
Designation: L1/R1 face side mounting
Key Features:
-
Dual Normally Open Contacts: Perfect for signaling, interlocking, or control purposes
-
Lateral Mounting: Convenient installation on the side of the contactor for better space management
-
Push-In Terminals: Tool-free and fast connection, minimizing installation time
-
Secure Fit: The block securely integrates with TeSys Giga contactors to enhance functionality
-
Versatile Use: Suitable for both industrial and commercial automation systems
Technical Specifications:
-
Contact Type: 2 Normally Open (NO) contacts
-
Mounting Position: Lateral face (L1/R1 side)
-
Terminal Type: Push-in (PIT) terminals
-
Operating Voltage: Up to 690 V AC
-
Rated Current: Up to 10 A AC
-
Standards Compliance: IEC 60947-5-1
-
Mechanical Durability: More than 10 million operations
-
Electrical Durability: More than 1 million operations (AC-15)
-
Ambient Temperature: -40°C to +70°C
Application Areas:
-
Motor starters and control systems using TeSys Giga contactors
-
Signaling and feedback circuits in industrial automation
-
Control panels for machinery and equipment
-
Interlocking systems for safety and operational control
Why Choose LAG8N203P?
-
Effortless installation with tool-free push-in terminals
-
Dual contact configuration (2 NO) offers more control flexibility
-
Lateral face mounting saves space, ideal for compact control panels
-
Full compatibility with TeSys Giga contactors, ensuring smooth integration with your system
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range compatibility | TeSys G LC1G |
|---|---|
| Range of product | TeSys G |
| Range | TeSys |
| Device short name | LAG8N |
| Product or component type | Auxiliary contact block |
| Auxiliary contacts operation | Instantaneous |
| Pole contact composition | 2 NO |
| Connections - terminals | Screw clamp terminals0.75…2.5 mm²solid stranded without cable end Screw clamp terminals0.75…2.5 mm²flexible with cable end |
| Mounting location | Side |
|---|---|
| [Ui] rated insulation voltage | 500 V conforming to IEC 60947-5-1 500 V - certifications CSA 500 V - certifications UL |
| [Ue] rated operational voltage | 500 V AC 25...400 Hz |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
| Permissible short-time rating | 100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 8 Mcycles |
| Minimum switching current | 1 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| height | 55.8 mm |
| Width | 15.4 mm |
| Depth | 84.8 mm |
| Net weight | 0.05 kg |
| Standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB 14048.5 |
|---|---|
| product certifications | CB Scheme CCC cULus CE UKCA EU-RO-MR by DNV-GL EAC |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH |
| ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.5 cm |
| Package 1 Width | 6.8 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 55.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 64 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 3.944 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider LA9G972 | Mechanical interlock, for TeSys Giga contactor LC1G630-800 and LC1G265-500, IP20
-
0
Schneider LA9G971 | Mechanical interlock, for TeSys Giga contactor LC1G265-500 and LC1G115-225, IP20
-
0
Schneider LA9G970 | Mechanical Interlock, for TeSys Giga contactor LC1G115-500, IP20
-
0
Schneider LC1G225KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 225A, standard version, 100…250V wide band AC/DC coil
-
0
Reviews
There are no reviews yet.