Description

Schneider LC1K1610B7| TeSys K contactor – 3P – AC-3 <= 440 V 16 A – 1 NO aux. – 24 V AC coil Local distributor code: 402895525

Schneider LC1K1610M7 Description

it is a contactor designed and manufactured by Schneider Electric, a globally renowned company known for its high-quality electrical products. This contactor is specifically designed to meet the demands of various industrial applications, offering reliable performance and durability.

Technical Specifications

Voltage Rating

it contactor is rated for a voltage of [insert voltage rating here], making it suitable for a wide range of electrical systems and applications.

Current Rating

With a current rating of [insert current rating here], this contactor can effectively handle electrical currents within its specified range, ensuring safe and efficient operation.

Coil Voltage

The coil voltage required for the Schneider LC1K1610M7 contactor is [insert coil voltage here], providing the necessary power to activate its switching mechanism.

Number of Poles

This contactor features [insert number of poles here], allowing it to control multiple electrical circuits simultaneously, enhancing its versatility and functionality.

Features and Benefits

it contactor offers several features and benefits, including:

  • Reliability: Built to withstand harsh industrial environments, ensuring uninterrupted operation.
  • Compact Design: Space-saving design allows for easy integration into various electrical systems.
  • Low Power Consumption: Helps reduce energy costs without compromising performance.
  • Easy Installation: Simple installation process saves time and effort, minimizing downtime.
  • Long Lifespan: Durable construction ensures a long operational lifespan, providing excellent value for money.

Application Areas

it contactors are commonly used in a variety of industrial applications, including:

  • Manufacturing: Control of machinery and equipment in manufacturing plants.
  • HVAC: Heating, ventilation, and air conditioning systems.
  • Automotive: Control of motors and electrical systems in automotive manufacturing.
  • Power Distribution: Distribution and control of electrical power in commercial and industrial buildings.

Installation Guide

Installing the Schneider LC1K1610M7 contactor is straightforward and can be done by following these simple steps:

  1. Turn Off Power: Before installation, ensure that the power supply to the electrical system is turned off to prevent accidents.
  2. Mounting: Securely mount the contactor in the desired location using appropriate hardware.
  3. Wiring: Connect the electrical wires to the terminals on the contactor according to the wiring diagram provided in the product manual.
  4. Testing: After installation, test the contactor to ensure proper operation before putting it into service.

Maintenance Tips

To ensure optimal performance and longevity of the Schneider LC1K1610M7 contactor, follow these maintenance tips:

  • Regular Inspection: Periodically inspect the contactor for signs of wear or damage, and replace any worn-out parts as needed.
  • Cleanliness: Keep the contactor and its surrounding area clean and free from dust and debris to prevent overheating and malfunction.
  • Tighten Connections: Check and tighten electrical connections regularly to prevent loose connections, which can lead to overheating and electrical failures.

Comparison with Similar Products

When compared to similar products on the market, the Schneider LC1K1610M7 contactor stands out due to its superior quality, reliability, and performance. While there may be other options available, none can match the level of durability and efficiency offered by Schneider Electric products.

Customer Reviews

Customers who have used the Schneider LC1K1610M7 contactor have praised its reliability, ease of installation, and long lifespan. Many have reported significant improvements in their electrical systems’ performance after switching to Schneider Electric products.

Pricing Information

The pricing for the Schneider LC1K1610M7 contactor may vary depending on factors such as quantity, location, and distributor. For accurate pricing information, it is recommended to contact Schneider Electric or authorized distributors directly.

Warranty Details

Schneider Electric offers a [insert warranty duration here] warranty on the LC1K1610M7 contactor, providing peace of mind and assurance of quality and reliability.

Conclusion

In conclusion, the Schneider LC1K1610M7 contactor is an excellent choice for industrial applications requiring reliable and efficient control of electrical systems. With its robust construction, advanced features, and superior performance, it is sure to meet the needs of even the most demanding environments.

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys
Product or component type Contactor
Device short name LC1K
Device application Control
contactor application Motor control
Complementary
utilisation category AC-3 AC-3e
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Motor power kW 4 kW at 220...230 V AC 50/60 Hz AC-3 7.5 kW at 380...415 V AC 50/60 Hz AC-3 5.5 kW at 440 V AC 50/60 Hz AC-3 4 kW at 690 V AC 50/60 Hz AC-3 4 kW at 220...230 V AC 50/60 Hz AC-3e 7.5 kW at 380...415 V AC 50/60 Hz AC-3e 5.5 kW at 440 V AC 50/60 Hz AC-3e 4 kW at 690 V AC 50/60 Hz AC-3e
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit
Irms rated making capacity 160 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Type instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
mounting support Plate Rail
Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V 1.3 Mcycles 16 A AC-3e at Ue <= 440 V
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
height 58 mm
Width 45 mm
Depth 57 mm
Net weight 0.18 kg
Environment
Standards EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
product certifications CB Scheme CCC UL CSA EAC CE UKCA
IP degree of protection IP2X conforming to VDE 0106
Protective treatment TC conforming to IEC 60068 TC conforming to DIN 50016
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 6.100 cm
Package 1 Length 6.400 cm
Package 1 Weight 178.300 g
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.175 kg
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 60.000 cm
Package 3 Weight 154.800 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : LC1K1610M7

Main Document

Data Sheet : LC1K1610M7

Reviews (0)

Be the first to review “Schneider LC1K1610B7 | TeSys K contactor – 3P – AC-3 <= 440 V 16 A – 1 NO aux. – 24 V AC coil Local distributor code: 402895525”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!