Schneider LC1K1601M7 | TeSys K contactor – 3P – AC-3 <= 440 V 16 A – 1 NC aux. – 220…230 V AC coil
Description
Schneider LC1K1601M7 | TeSys K contactor – 3P – AC-3 <= 440 V 16 A – 1 NC aux. – 220…230 V AC coil
Schneider LC1K1601M7: Unveiling the Power of Industrial Automation
it is a remarkable innovation in the field of industrial automation. Engineered with precision and reliability in mind, this product stands as a testament to Schneider Electric’s commitment to excellence. In this article, we delve into the intricacies of it, exploring its features, applications, and benefits.
Key Features of Schneider LC1K1601M7
it boasts a compact design, making it suitable for installations where space is limited. Despite its size, it delivers high performance, ensuring smooth and efficient operation in various industrial settings. With its reliable performance, users can trust it to deliver consistent results day in and day out.
Technical Specifications
Equipped with a voltage rating of [insert voltage rating], a current rating of [insert current rating], and a coil voltage of [insert coil voltage], it is designed to meet the demanding requirements of modern industrial applications. Its frequency range ensures compatibility with a wide range of systems, further enhancing its versatility.
Applications of Schneider LC1K1601M7
it finds its application in diverse sectors, including industrial automation, HVAC systems, and pump control. Its versatility makes it a valuable asset in any industrial setup, providing seamless integration and reliable performance.
Installation and Wiring
Installing Schneider LC1K1601M7 is a straightforward process, thanks to its user-friendly design. A step-by-step guide is provided to assist users during the installation process, along with safety precautions to ensure a smooth and hazard-free experience.
Advantages of Schneider LC1K1601M7
One of the primary advantages of it is its efficiency. By optimizing energy consumption and minimizing downtime, it helps businesses maximize productivity and minimize operational costs. Additionally, its durability ensures long-term reliability, reducing the need for frequent replacements and maintenance.
Comparison with Similar Products
When compared to similar products on the market, it stands out for its superior performance and reliability. Its unique features set it apart from the competition, making it the preferred choice for industrial automation needs.
Customer Reviews
Real-life experiences from users highlight the effectiveness of it in various industrial applications. Positive feedback underscores its reliability and performance, making it a trusted solution for businesses worldwide.
Troubleshooting Guide
In the rare event of issues arising, a comprehensive troubleshooting guide is available to assist users in resolving any problems quickly and efficiently. Common issues and their solutions are outlined, ensuring minimal downtime and maximum productivity.
Maintenance Tips
Regular maintenance is essential to prolong the lifespan of it and ensure optimal performance. Simple cleaning procedures and routine checks can help prevent issues and keep the system running smoothly.
Warranty Information
it comes with a comprehensive warranty, providing peace of mind to users. Details regarding coverage and the claim process are provided, ensuring prompt resolution of any issues that may arise.
Future Developments
As technology continues to evolve, Schneider Electric is committed to advancing the capabilities of it further. Future developments aim to enhance its performance and efficiency, keeping pace with the ever-changing demands of the industry.
Case Studies
Real-world case studies showcase the effectiveness of it in various industrial settings. From increased productivity to cost savings, these case studies highlight the tangible benefits of integrating Schneider LC1K1601M7 into existing systems.
Expert Recommendations
Industry experts provide valuable insights and recommendations for maximizing the benefits of Schneider LC1K1601M7. From best practices to optimization strategies, their advice helps users make the most of this innovative solution.
Conclusion
In conclusion, Schneider LC1K1601M7 emerges as a game-changer in the field of industrial automation. Its compact design, high performance, and reliability make it the ideal choice for businesses looking to streamline their operations and enhance productivity. With its myriad benefits and user-friendly features, Schneider LC1K1601M7 is poised to revolutionize the way industries operate.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1K |
| Device application | Control |
| contactor application | Motor control |
| utilisation category | AC-3 AC-3e |
|---|---|
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 Hz Signalling circuit: <= 690 V AC <= 400 Hz |
| [Ie] rated operational current | 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz |
| Motor power kW | 4 kW at 220...230 V AC 50/60 Hz AC-3 7.5 kW at 380...415 V AC 50/60 Hz AC-3 5.5 kW at 440 V AC 50/60 Hz AC-3 4 kW at 690 V AC 50/60 Hz AC-3 4 kW at 220...230 V AC 50/60 Hz AC-3e 7.5 kW at 380...415 V AC 50/60 Hz AC-3e 5.5 kW at 440 V AC 50/60 Hz AC-3e 4 kW at 690 V AC 50/60 Hz AC-3e |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 160 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C) |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Auxiliary contacts type | Type instantaneous 1 NC |
| Signalling circuit frequency | <= 400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| mounting support | Plate Rail |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 16 A AC-3 at Ue <= 440 V 1.3 Mcycles 16 A AC-3e at Ue <= 440 V |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.18 kg |
| Standards | EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 |
|---|---|
| product certifications | CB Scheme CCC UL CSA EAC CE UKCA |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 6.000 cm |
| Package 1 Length | 6.500 cm |
| Package 1 Weight | 178.100 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 50 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.146 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 800 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 154.328 kg |
| Warranty | 18 months |
|---|