Description

Schneider  LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil

Product Overview: Schneider LC1K0610B7 Contactor

The Schneider Electric LC1K0610B7 is a compact and efficient contactor from the TeSys K series, ideal for use in control circuits and motor applications.

Key Features:

  • Brand: Schneider Electric

  • Series: TeSys K

  • Model Number: LC1K0610B7

  • Type: Electromechanical Contactor

  • Application: Control of motors and electrical loads

Electrical Specifications:

  • Rated Operational Current (Ie):
    – Up to 6A under AC-3 utilization category

  • Operational Voltage:
    – Supports up to 440V AC

  • Poles:
    3-Pole (3P) main contacts

  • Auxiliary Contact Configuration:
    1 NO (Normally Open) auxiliary contact

Coil Characteristics:

  • Control Voltage:
    24V AC (Volts Alternating Current)

  • Coil Frequency:
    50/60 Hz

Design and Mounting:

  • Compact Design:
    – Saves space in panels

  • Mounting Type:
    – DIN rail or panel mounting

  • Conformity:
    – Compliant with IEC standards for reliability and safety

Applications:

  • Motor control up to 3 kW (depending on voltage)

  • Lighting circuits

  • HVAC systems

  • Industrial control panels

  • Switching of resistive and inductive loads

Benefits:

  • Reliable operation in harsh environments

  • Compact size for small enclosures

  • Easy installation and maintenance

  • Energy-efficient coil design

  • Long mechanical and electrical life

Typical Industries:

  • Industrial Automation

  • Commercial Buildings

  • HVAC and Refrigeration

  • Water Treatment Plants

  • Packaging and Machinery

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys
Product or Component Type Contactor
Device short name LC1K
Device Application Control
contactor application Motor control
Complementary
utilisation category AC-3 AC-3e AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Motor power kW 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA 4.5 VA (at 68 °F (20 °C))
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
Connections - terminals Screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting Support Rail Plate
Tightening torque 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm 11.51 lbf.in (1.3 N.m) lugs-ring terminals pozidriv No 2
Operating time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance 0.02 in (0.5 mm)
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height 2.28 in (58 mm)
Width 1.77 in (45 mm)
Depth 2.24 in (57 mm)
Net Weight 0.40 lb(US) (0.18 kg)
Environment
Standards EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
Product Certifications CB Scheme CCC UL CSA EAC CE UKCA
IP degree of protection IP2X VDE 0106
Protective treatment TC IEC 60068 TC DIN 50016
Ambient Air Temperature for Storage -58…176 °F (-50…80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Ordering and shipping details
Category US10I1222326
Discount Schedule 0I12
GTIN 3389110365139
Returnability Yes
Country of origin FR
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.97 in (5.000 cm)
Package 1 Width 2.36 in (6.000 cm)
Package 1 Length 2.56 in (6.500 cm)
Package 1 Weight 6.28 oz (178.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 5.91 in (15.000 cm)
Package 2 Width 11.81 in (30.000 cm)
Package 2 Length 15.75 in (40.000 cm)
Package 2 Weight 20.16 lb(US) (9.143 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 29.53 in (75.000 cm)
Package 3 Width 31.50 in (80.000 cm)
Package 3 Length 23.62 in (60.000 cm)
Package 3 Weight 340.15 lb(US) (154.288 kg)
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : LC1K0610B7

Main Document

Data Sheet : LC1K0610B7

Reviews (0)

Be the first to review “Schneider LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare